• Am. J. Vet. Res. · Dec 2007

    Clinical Trial

    Use of bispectral index to monitor depth of anesthesia in isoflurane-anesthetized dogs.

    • Daniela Campagnol, Francisco J Teixeira Neto, Eduardo R Monteiro, Suzane L Beier, and Antônio J A Aguiar.
    • Department of Veterinary Surgery and Anesthesiology, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista (UNESP), Botucatu, São Paulo, Brazil.
    • Am. J. Vet. Res. 2007 Dec 1; 68 (12): 1300-7.

    ObjectiveTo evaluate the correlation between the bispectral index (BIS) and end-tidal isoflurane (ET(ISO)) concentration and compare the use of 3 BIS sensor positions in dogs.Animals6 adult dogs.ProceduresMechanically ventilated dogs received pancuronium, and depth of anesthesia was altered by increasing ET(ISO) concentration from 1.5% to 2.3% and 3.0%. The BIS, suppression ratio (relative percentage of isoelectric electroencephalographic waveforms), and signal quality index (SQI) were recorded at each ET(ISO) concentration for each of 3 BIS sensor positions (frontal-occipital, bifrontal, and frontal-temporal positions).ResultsThe BIS and ET(ISO) concentration were poorly correlated; regardless of sensor positioning, mean BIS values did not change significantly as ET(ISO) was increased. At 3% isoflurane, regardless of sensor positioning, there was an increase in suppression ratio coincident with BIS < 40 in some dogs, whereas paradoxic increases in BIS (> 60) were recorded in others. Furthermore, at 3.0% isoflurane, the SQI was significantly lower for the bifrontal sensor position (compared with values for the other positions), but low SQI values prevented recording of BIS values from the frontal-occipital sensor position in 2 dogs. Overall, BIS values derived from the 3 sensor positions did not differ.Conclusions And Clinical RelevanceIn dogs, BIS values may not reflect changes in depth of isoflurane anesthesia in the absence of noxious stimulation. Of the 3 sensor positions, frontal-temporal positioning provided better correlation with changes in depth of anesthesia induced via changes in isoflurane concentrations. However, the sensor placements yielded similar results at SQI values > 50.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.