- James P AuBuchon, Mark Fung, Barbee Whitaker, and Jacquelyn Malasky.
- Puget Sound Blood Center, Seattle, Washington.
- Transfusion. 2014 Aug 1; 54 (8): 2077-83.
BackgroundThe utility of a hemovigilance system depends on appropriate, reproducible application of system definitions. This is even more important when submissions are not reviewed by an adjudicating body. We sought to determine how participants would code adverse reactions at institutions that had or had not received training on the application of definitions used in the CDC's National Healthcare Safety Network Hemovigilance Module (HVM).Study Design And MethodsFacilities that were (11) or were not (11) submitting adverse reaction data to the HVM reviewed 36 hypothetical cases containing elements of 37 case definitions from 12 different diagnostic groups. Respondents were required to determine the type of adverse event, if any, and assign a case definition (diagnostic probability), severity, and imputability using the January 2013 HVM Surveillance Protocol definitions. Those submitting HVM data had access to an instructional slide set prepared by CDC using similar hypothetical cases. Concordance with expert analysis was determined for the two groups of respondents.ResultsThe frequencies of agreement with the expert assessment were not different according to prior training exposure in any of the diagnostic groups, and results were totaled across both groups. Response accuracy varied by type of categorization (adverse event type, 72.1%; match with case definition, 76.5%; severity, 69.6%; imputablity, 64.4%) and by type of adverse event.ConclusionDespite delineated definitions, considerable variability in responses was seen, and this was not reduced by the available training. This degree of inconsistency in application of the surveillance definitions could degrade the utility of comparative reports.© 2014 AABB.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.