    Update on value of the anion gap in clinical diagnosis and laboratory evaluation.

    • P H Lolekha, S Vanavanan, and S Lolekha.
    • Department of Pathology, Division of General Clinical Chemistry, Ramathibodi Hospital, Mahidol University, 10400, Bangkok, Thailand. raptl@mahidol.ac.th
    • Clin. Chim. Acta. 2001 May 1; 307 (1-2): 33-6.

    AbstractAnion gap (AG) is a calculated value commonly used in clinical practice. It approximates the difference between the concentration of unmeasured anions (UA) and unmeasured cations (UC) in serum. At present, the reference range of anion gap has been lowered from 8-16 to 3-11 mmol/l because of the changes in technique for measuring electrolyte. However, clinicians and textbooks still refer and use the old reference value of 8-16 mmol/l. This may lead to misinterpretation of the value of anion gap. Our study updated the value of anion gap in clinical diagnosis and laboratory evaluation. Criteria for using anion gap were also suggested. We analyzed serum electrolyte using the Beckman Synchron CX5. The anion gap was calculated from the formula: [Na(+)-(Cl(-)+HCO(3)(-))]. We estimated the reference range using the non-parametric percentile estimation method. The reference range of anion gap obtained from 124 healthy volunteers was 5-12 mmol/l, which was low and confirmed the reports from other studies (3-11 mmol/l) using ion-selective electrode. From the retrospective study on the 6868 sets of serum electrolyte among hospitalized patients, we found the incidences of normal, increased, and decreased anion gaps were 59.5%, 37.6%, and 2.9%, respectively. The mean and central 90% range of increased anion gap were 16 and 13-20 mmol/l, which was lower than those reported in previous study (25 and 19-28 mmol/l). Anion gap exceeding 24 mmol/l was rare. The mean and central 90% range of decreased anion gap were 3 and 2-4 mmol/l, which were lower than those reported in previous study (6 and 3-8 mmol/l). The value of less than 2 mmol/l was rare. The most common causes of increased anion gap (hypertensive disease, chronic renal failure, malignant neoplasms, diabetes mellitus and heart diseases) and decreased anion gap (liver cirrhosis and nephrotic syndrome) in this study were similar to those in previous studies. We found two cases of IgG multiple myeloma with anion gap of 2 mmol/l. In conclusion, clinicians and laboratorians can use the anion gap as clue in quality control. They can check the incidences of increased and decreased anion gap. If one finds high incidence of increased anion gap (>24 mmol/l) or decreased anion gap (<2 mmol/l), one should check the quality control of electrolyte and whether the patients were hypoalbuminemia or hyperglobulinemia. An anion gap exceeding 24 mmol/l will suggest the presence of metabolic acidosis. It is very rare to find anion gap with the negative sign.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.