- Christian P Dipaola, Justin A Jacobson, Hani Awad, Bryan P Conrad, and Glenn R Rechtine.
- University of Rochester Medical Center, Rochester, NY 14642, USA. cpd62@yahoo.com
- Spine J. 2008 Sep 1; 8 (5): 717-22.
Background ContextTwo common justifications for orienting cervical screws in an angled direction are to increase pullout strength and to allow use of longer screws. This concept is widely taught and has guided implant design. Fixed- versus variable-angle systems may offer strength advantages. Despite these teachings, there is a paucity of supporting biomechanical evidence. The purpose of our study is to test the influence of screw orientation and plate design on the maximum screw pullout force.PurposeThis study evaluates the effect of screw orientation and plate type (fixed- vs. variable-angle) on screw pullout strength.Study DesignAnterior cervical plates of both a fixed- and variable-angle CSLP, were tested for peak pullout strength in a direct plate pullout model using polyurethane foam bone, which models osteoporotic bone.MethodsSelf-tapping, locking screws (4.0x14mm and 4.0x16mm) were used. Screws were oriented in the fixed-angle plate in the standard fashion. In the variable plate, screws were instrumented in three different orientations. Biomechanical testing was performed on an Instron DynaMight 8841 servohydraulic testing machine, measuring maximum pullout force under a displacement-controlled pullout rate of 1mm/min. Five samples were tested per group.ResultsWhen all screws were placed 90 degrees to the plate, there was a significantly increased peak pullout strength (412.8+/-22.2N) compared with when all screws were placed 12 degrees "up and in" (376.2+/-24.3N, p less than or equal to .03). When the 90 degrees construct was reproduced using 14-mm screws and compared with 16-mm screws oriented 12 degrees "all up and in," there was still significantly higher pullout strength with the all 90 degrees construct (434.2+/-28.7N vs. 376.2+/-24.3N, p less than or equal to .009). The fixed-angle plate had a significantly decreased peak pullout strength (288.2+/-15.7N) compared with the variable-angle plate (416.6+/-12.6N) (p less than .00001) when the screws were placed in the same orientation. Overall, the variable-angle plate, regardless of the orientation of screws, had a significantly greater pullout strength than the fixed-angle plate (p less than .001).ConclusionsIn this system, a variable-angle plate has greater pullout strength than a fixed-angle plate, regardless of the orientation of screws. With the variable-angle plate, a construct of all screws 12 degrees "up and in" is the weakest configuration. We found that with the 90 degrees construct, both 16- and 14-mm screws performed significantly better than 16-mm convergent screws. These findings are remarkable because they contradict the current doctrine. This may be a function of plate-dependent factors and should not be applied universally to all plate systems. Further study of screw orientation in additional plating systems is warranted.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.