-
- Paul F Heini and C Dain Allred.
- Department of Orthopaedic Surgery, Spine Service, Inselspital, University of Bern, Switzerland. paul.heini@insel.ch
- Spine. 2002 Jan 1; 27 (1): 105-9.
Study DesignA human cadaveric investigation was conducted to determine the effect that a side-opening injection cannula in monopedicular percutaneous vertebroplasty had on the vertebrae filling pattern.ObjectivesTo assess the filling pattern in vertebroplasty using a monopedicular technique, and to compare a standard front-opening filling cannula with a side-opening cannula.Summary Of Background DataVertebroplasty is an effective treatment for osteoporotic vertebral fractures. Clinical and biomechanical investigations show its efficacy even in asymmetrical filling patterns. However, the risk of cement extravasation is a major concern with this technique.MethodsTwo different bone cement-injecting cannulas were compared: a standard front-opening cannula (8 gauge, 6 inches long) and a cannula of the same dimensions with a side-opening at its distal end. Eight pairs of osteoporotic nonfractured cadaver vertebrae (T10-T11) were augmented with low-viscosity polymethylmethacrylate under axial C-arm control. The filling pattern was assessed semiquantitatively. The cross-section in its lateral extension was divided into four equal bands, and the appearance of the cement in each respective zone was assessed after cement injections of 2, 4, and 8 mL. The extravasation of bone cement also was monitored.ResultsWith the side-opening cannula, the cement flow reached Zone 3 in six of eight cases, whereas with the front-opening cannula, the polymethylmethacrylate was observed in Zone 3 in only three cases. In no case was the cement observed in Zone 4. In five of eight cases using front-opening cannulas, extravasation into the vessels was observed after 3 to 4 mL of bone cement had been injected. No extravasation was noted with the use of the side-opening cannula unless the amount of cement exceeded 8 mL.ConclusionsA side-opening cannula can improve the cement-filling pattern in monopedicular vertebroplasty, as compared with a standard front-opening cannula. The risk of extravasation is diminished if the cement flow is directed medially.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.