BackgroundEffects of direct radiation on implantable cardiac devices have been well studied. However, the effects of scatter radiation are not as clear. Recommendations on management of patients with implantable cardiac devices undergoing radiotherapy are based on limited studies mostly involving pacemakers. We sought to elucidate the effects of scatter radiation on implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy (CRT)-ICDs.MethodsWe exposed 12 ICDs and eight CRT-ICDs to 400 cGy of scatter radiation from a 6-MV photon beam. Devices were programmed with nominal parameters and interrogated prior to radiation, after each fraction, upon completion of the radiation course and again 1 week later. A retrospective review of patients undergoing radiotherapy at the Mayo Clinic-Rochester between 2002 and 2007 in whom the device was outside the radiation field was also performed. There were 13 patients with devices undergoing radiotherapy during this time period, 12 of whom were interrogated prior to and after radiation.ResultsInterrogation reports were reviewed for device reset or parameter changes. There was no evidence of reset or malfunction during or after radiation. Also, no episodes of device reset, inappropriate sensing or therapy, or changes in programmed parameters were found in our review of patients undergoing radiotherapy.ConclusionsDevice reset or malfunction associated with scatter radiation likely represents an unpredictable, rare occurrence. While we see no clear contraindication to radiotherapy in patients with ICDs or CRT-ICDs, precautions should be taken to avoid direct radiation exposure and to closely evaluate patient outcomes before and after the radiation course.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.