• Dis. Colon Rectum · Dec 2010

    Comparative Study

    The digital rectal examination scoring system (DRESS).

    • Bruce A Orkin, Svetlana B Sinykin, and Patricia C Lloyd.
    • The Division of Colon and Rectal Surgery, Tufts Medical Center, Boston, Massachusetts 02111, USA. borkin@tuftsmedicalcenter.org
    • Dis. Colon Rectum. 2010 Dec 1; 53 (12): 1656-60.

    PurposeAssessment of anal sphincter tone is a critical part of anorectal examination, yet no standardized, quantifiable method for describing anal sphincter tone on digital rectal examination exists. We developed a novel scoring system for anal sphincter tone using a scale of 0 to 5 for both resting pressure and squeeze pressure. The score ranges from 0 = no discernable pressure to 5 = extremely tight and 3 = normal. We hypothesized that the digital rectal examination scoring system (DRESS) score would correlate with anorectal manometry pressures.MethodsThree hundred three patients (mean age, 51 y; range, 28-86 y) who had a DRESS score and a concurrent manometry test (1998-2008) were identified from a prospective database. Means of 4 quadrant manometry at rest and with squeeze were compared with the resting pressure and squeeze pressure DRESS scores at each point from 0 to 5. Box plots for manometry results by DRESS score were graphed. ANOVA using a significance level of α = .05 tested whether each of the DRESS scores were different from one another. Spearman rank correlation coefficients assessed associations between manometry and DRESS results.ResultsManometric pressures (mmHg; mean ± SEM) for DRESS resting pressure values 0 to 5 were 20.6 ± 2.1, 38.5 ± 2.0, 47.8 ± 1.6, 72.3 ± 1.5, 94.4 ± 2.9, and 128.0 ± 6.7, respectively. Pressures for DRESS squeeze pressure values 0 to 5 were 45.9 ± 5.6, 66.5 ± 3.2, 108.2 ± 4.9, 156.3 ± 4.5, 238.6 ± 9.8, and 368.2 ± 49.1. Box plots demonstrated clear differences between each DRESS score and positive progression from 0 to 5 for both resting pressure and squeeze pressure. ANOVA analysis showed a significant difference in mean manometry measurements at all levels of digital rectal examination, both for resting pressure and squeeze pressure (P < .001). Spearman rank correlations showed a strong positive correlation between the DRESS values and manometry pressures with coefficients of 0.82 for resting pressure and 0.81 for squeeze pressure.ConclusionsThe DRESS score correlated very well with manometry pressures for resting pressure and squeeze pressure. The DRESS system may be a useful description of anal sphincter resting pressure and squeeze pressure in the clinical setting. Further validation may support adoption of the DRESS system as part of the standard anorectal examination.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…