-
J Clin Monit Comput · Jun 2004
Comparative StudyA novel approach to measure cardiac output noninvasively: a comparison with the thermodilution method on critical care patients.
- John Kabal and Bruce K Lagerman.
- Reston Noninvasive Hemodynamic Center 1712 Clubhouse Road, Suite 103 Reston, Virginia 20190, USA.
- J Clin Monit Comput. 2004 Jun 1; 18 (3): 189-97.
ObjectiveTo compare the accuracy and reliability of cardiac output (CO) measurement by a Noninvasive Hemodynamic Analyzer (NHA) to the thermodilution cardiac output (COTD) technique in ICU patients of cardiac condition.MethodICU retrospective data collected in a 700-bed university-affiliated regional medical center. The data results from 203 patients who required invasive hemodynamic monitoring for clinical and/or surgical management.ResultsThe ranges of the two CO measurements were: CO(TD) = 2.06 to 8.8 l/min and CO(NHA) = 2.06 to 8.46 l/min, respectively. The Mean and SD of CO(NHA) = 4.819 l/min +/- 1.053 was near to CO(TD) = 4.902 l/min +/- 1.421. Variance was better for CO(NHA) = 1.110 l/min compared to CO(TD) = 1.421 l/min. Median of CO(NHA) showed 4.813 l/min and CO(TD) = 4.660 l/min. Bias was 0.083 l/min with 95% Confidence Interval (Precision): -0.26 to 0.040, and 95% Limits of Agreement was between -1.661 to 1.827 l/min.ConclusionsThe results of this retrospective study indicate that the CO(NHA) technique may be a promising screening method. Additional studies are needed to explore its diagnostic trending capability. This noninvasive CO technique has been proven to be clinically accurate and may be applicable for telemedicine applications.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.