- M Kurusz, D J Deyo, A D Sholar, W Tao, and J B Zwischenberger.
- Department of Surgery, The University of Texas Medical Branch, Galveston 77555-0528, USA. mkurusz@utmb.edu
- Perfusion. 1999 Sep 1; 14 (5): 379-87.
AbstractFemoral venous cannulae (17-28 French) were tested to compare flows obtained by their placement in a simulated inferior vena cava (IVC) or right atrium (RA) and by varying drainage pressures using gravity siphon drainage or a centrifugal pump in the venous line. The circuit consisted of conventional tubing and equipment including a segment of thin-walled latex tubing to simulate the IVC connected to a flexible reservoir to simulate the RA. The test fluid was a 40% glycerin solution. Flow was measured at height differentials of 30-60 cm (cannula-to-inlet of hard-shell venous reservoir) and with a -10 to -80 mmHg negative pressure created by the centrifugal pump. A roller pump returned the test fluid to a flexible bag to maintain a filling pressure of 0-1 mmHg. Flow increased modestly with an increasing height differential. When negative pressure was applied with the centrifugal pump, flow increased 10% and 18% (IVC and RA positions, respectively) compared to gravity siphon drainage conditions. There also was a tendency for flow to plateau or cease when the centrifugal pump was used at higher levels of negative pressure or when larger cannulae were used. We conclude: (1) position of smaller cannulae in the RA yield better flows than when the cannulae are larger and placed in the IVC; (2) smaller-sized cannulae are capable of achieving higher flows when the centrifugal pump is used; (3) cannulae must be properly positioned to achieve maximum flow; (4) the centrifugal pump will augment flow, but should be regulated to avoid extreme negative pressures; and (5) cannula design has no demonstrable effect on flow.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.