-
Comparative Study
Reliability of a new hand-held device for the measurement of exhaled nitric oxide.
- B Khalili, P B Boggs, and S L Bahna.
- Louisiana State University Health Sciences Center - Allergy & Immunology, Shreveport, LA 71103, USA.
- Allergy. 2007 Oct 1; 62 (10): 1171-4.
BackgroundGiven the importance of airway inflammation in asthma, there has been an effort to incorporate inflammatory markers into its management. Measurement of fractional exhaled nitric oxide (FeNO) is a noninvasive marker of airway inflammation; however, the use of the available FeNO analyzer is limited by several factors including its cost and lack of transportability. The aim of this study was to compare the performance of a new hand-held FeNO measuring device (NIOX MINO) to the current clinical standard - the chemiluminescence FeNO analyzer (NIOX).MethodsSubjects 6 years and older presenting to an allergy and asthma clinic underwent FeNO evaluation by NIOX and each of three NIOX MINOs. The mean of two acceptable measurements from the NIOX and the first approved measurement from each NIOX MINO were used for analysis.ResultsOne hundred ten patients aged 6-86 years completed the study. Intrasubject FeNO levels obtained by each of the three NIOX MINOs revealed no significant difference between the measurements (P = 0.59). There was a very strong correlation between FeNO measurements by NIOX and by NIOX MINO (r = 0.98, P < 0.0001). The mean intrasubject FeNO difference between NIOX and NIOX MINO was -0.5 p.p.b. which was not statistically significantly different from zero (P = 0.21).ConclusionsFractional exhaled nitric oxide measurements by the NIOX MINO showed a strong correlation and a high degree of agreement with the current standard stationary device. The NIOX MINO may be reliably used in clinical practice.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.