• Pain Med · Oct 2014

    A quantitative study of intervertebral disc morphologic changes following plasma-mediated percutaneous discectomy.

    • Matthew Smuck, Joshua Levin, Eric Zemper, Adil Ali, and David J Kennedy.
    • PM&R Section, Department of Orthopaedic Surgery, Stanford University, Redwood City, California, USA.
    • Pain Med. 2014 Oct 1;15(10):1695-703.

    ObjectiveTo quantitatively evaluate interval magnetic resonance imaging (MRI) changes in disc morphology following plasma-mediated percutaneous discectomy.Design/SettingA retrospective comparison of pretreatment and posttreatment MRIs at a single university spine clinic.SubjectsFrom a group of 60 consecutively treated patients, 15 met the study inclusion and exclusion criteria. All had either failed treatment or had other clinical reasons for a posttreatment MRI.MethodsTwo independent physicians electronically measured disc protrusion size and disc height at the treatment discs and adjacent discs on pre- and posttreatment MRI scans. Additionally, images were compared for gross anatomic changes including disc degeneration by Pfirrman classification, new disc herniations, high intensity zone (HIZ), vertebral endplate changes, post-contrast enhancement, and changes in segmental alignment. Pearson r correlation was used to determine interobserver reliability between the two physicians' MRI measurements. Paired t-tests were calculated for comparisons of pre- and posttreatment MRI measurements, and an ANOVA was performed for comparison of pre- to posttreatment changes in disc height measurements at treatment levels relative to adjacent levels.ResultsCorrelation was high for measurement of disc height change (r = 0.89; P < 0.0001) and good for anteroposterior protrusion size change (r = 0.51; P = 0.0512). Disc height at treated discs demonstrated a small but statistically significant mean interval reduction of 0.48 mm (P = 0.0018). This remained significant when compared with the adjacent control discs (P < 0.0001). Pretreatment mean disc protrusion size (4.74 mm; range 3.75-6.55 mm) did not differ significantly (P = 0.1145) from posttreatment protrusion size (4.42 mm; range 2.55-7.95 mm). Gross anatomic changes at treatment levels included reduced disc protrusion size (N = 6), enlarged protrusion (N = 3), resolution of HIZ (N = 3), and improvement in endplate signal changes (N = 1). Also, 11/15 posttreatment MRIs included post-contrast images that showed epidural fibrosis (N = 1), rim enhancement (N = 2), and enhancement of the posterior annulus (N = 4).ConclusionsBased on MRI examinations, subtle anatomic changes may occur following plasma-mediated percutaneous discectomy. Further study is required to determine the clinical relevance of these changes.Wiley Periodicals, Inc.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.