• Hernia · Oct 2015

    Randomized Controlled Trial Comparative Study

    Randomised clinical trial: conventional Lichtenstein vs. hernioplasty with self-adhesive mesh in bilateral inguinal hernia surgery.

    • Jose L Porrero, María J Castillo, Ana Pérez-Zapata, María T Alonso, Oscar Cano-Valderrama, Esther Quirós, Sol Villar, Beatriz Ramos, Carlos Sánchez-Cabezudo, Oscar Bonachia, Alberto Marcos, and Brígido Pérez.
    • Servicio de Cirugía General y del Aparato Digestivo, Hospital Universitario Santa Cristina, Calle Maestro Amadeo Vives 2, 28009, Madrid, Spain.
    • Hernia. 2015 Oct 1; 19 (5): 765-70.

    PurposeTo compare the results of conventional Lichtenstein hernioplasty with polypropylene mesh (PLP) with a lightweight self-adhesive mesh (Parietene Progrip®; Covidien, Dublin, Ireland) (PPG) used in patients with bilateral inguinal hernia.MethodsRandomised clinical trial with 89 patients with a minimum follow-up of 1 year. Every patient had bilateral inguinal hernia and had both prostheses implanted randomly, one on each side. Early postoperative and chronic pain was evaluated using the visual analogue scale. Also recurrence rate and subjective evaluation of patients were analysed.ResultsPain in the early postoperative period was inferior on the side where the self-adhesive mesh had been implanted (6.12 vs. 6.62, p=0.005 during the 1st postoperative day; 2.12 vs. 2.62, p=0.001 during the 7th postoperative day). Differences disappeared with the long-term evaluation (0.71 vs. 0.98, p=0.148 1 year after the surgery). The operative time was significantly shorter on the PPG mesh side (24.37 ± 5.1 in case of the PPG mesh and 29.66 ± 5.6 in case of the PLP mesh, p<0,001). Recurrence occurred in seven patients (7.8%), six of them (6.7%, CI 3.0-14.4) on the PPG mesh side and one (1.1%, CI 0.2-7.8) on the PLP side. These differences were not statistically significant (p=0.125) CONCLUSIONS: Although hernioplasty with self-adhesive mesh reduced early postoperative pain, this reduction was clinically irrelevant and it had no influence on chronic pain. There was a trend towards a higher recurrence rate when self-adhesive meshes were used, and although in this study differences were not statistically significant they should be confirmed in later studies using larger samples. Surgical procedures that do not need fixing sutures are promising, but further studies are needed before they become the gold standard of inguinal hernia repair.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…