    ObjectiveThe purpose of this study was to evaluate the usefulness of a new parameter, pleural adenosine deaminase (PADA), for separating transudative pleural effusion from exudative pleural effusion, and to compare the results with other tests (albumin gradient and protein gradient).MethodsFrom November 2001 to January 2003, 359 consecutive patients with pleural effusion who underwent a diagnostic thoracentesis were included in the study. Effusions were individually classified as transudates or exudates after the careful evaluation of all clinical data and biochemical parameters of pleural fluid and serum of patients on the basis of Light's criteria. The means and standard deviations of PADA, pleural/serum ADA (P/S ADA) ratio, albumin gradient and protein gradient were evaluated for transudative and exudative effusions. The best cut-off values for each test were identified by using the receiver operating characteristic (ROC) curve. The optimum cut-off level was determined by selecting points of test values that provided the greatest sum of sensitivity and specificity.ResultsThere were 113 transudates and 246 exudates. For each test, differences in mean value between the transudate group and the exudate group were statistically significant (t test, P<0.001). The optimum cut-off levels for PADA and P/S ADA were 15.3 U/L and 0.66 U/L, respectively. ROC analysis confirmed previous recommendations for albumin gradient (12 g/L) and protein gradient (31 g/L). For detecting exudates, the PADA test yielded a sensitivity and specificity of 85.8% and 82.3%, respectively. Sensitivity and specificity of the albumin gradient were found to be 88.5% and 79.3%, and of the protein gradient 85% and 83.2%, respectively. The areas under the curve (AUC) data and accuracy demonstrated similar discriminative properties in the examined tests.ConclusionsThe measurement of PADA is suggested as a reliable test in the separation of pleural exudates from transudates with accuracy similar to that of the albumin gradient and protein gradient.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.