-
- Hiliary Shanahan, Rory O'Donoghue, Patrick O'Kelly, Aidan Synnott, and James O'Rourke.
- St James' Hospital, Dublin, Ireland.
- Eur J Anaesthesiol. 2012 May 1;29(5):229-34.
ContextMalignant hyperthermia may follow exposure to trace quantities of inhalational anaesthetics. In susceptible patients, the complete avoidance of these triggers is advised when possible; however, failing this, it is essential to washout or purge the anaesthesia machine of residual inhalational anaesthetics.ObjectiveThis study examined the washout profile of sevoflurane from the Drager Fabius CE and the Drager Zeus machines.DesignThe washout profile of sevoflurane was measured from the Fabius CE and Zeus anaesthesia machines following a standard period of exposure. The disposable tubing, CO2 absorber and other components of each machine were then replaced to examine their impact on the retention of sevoflurane. The effect of autoclaving the ventilator diaphragm and non-disposable ventilator tube or substituting for a new diaphragm and ventilation tube were examined in later parts of this study.SettingUniversity teaching hospital.Main Outcome MeasureTime taken to reach 5 parts per million of sevoflurane when machines underwent standard washout with fresh gas flush.ResultsThe concentration of sevoflurane reached 5 parts per million in the Fabius CE machines after an mean (SD) of 140 min (46) at a fresh gas flow (FGF) of 10 l min(-1). The time taken for sevoflurane to reach 5 parts per million was significantly reduced when the ventilator diaphragm and non-disposable tube were replaced with either new or autoclaved components [14 or 22 min, respectively (P = 0.017, P = 0.031)]. The concentration of sevoflurane reached 5 parts per million in the Zeus machines after an mean (SD) of 85 min (6) at a fresh gas flow of 10 l min(-1). When the fresh gas flow was increased to 18 l min(-1) (the maximum allowable), the time to reach 5 parts per million was reduced to 16 min.ConclusionWhen preparing the Fabius CE for the malignant hyperthermia susceptible patient, remove the vaporiser, replace the disposable tubing, the reservoir bag and the CO2 absorber. Replace the ventilator diaphragm and non-disposable ventilator tube with new or autoclaved components and flush the machine at 10 l min(-1) for at least 36 min. When preparing the Zeus, remove the vaporiser, replace the disposable tubing, the reservoir bag and CO2 absorber and flush at a fresh gas flow of 10 l min(-1) for at least 90 min. In both the Fabius and Zeus, continue at a fresh gas flow of 10 l min(-1) for the duration of the operation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.