-
Review Meta Analysis
Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis.
- Konstantinos A Polyzos, Athanasios A Konstantelias, and Matthew E Falagas.
- Alfa Institute of Biomedical Sciences (AIBS), 9 Neapoleos Street, 151 23 Marousi, Athens, Greece Atherosclerosis Research Unit, Center for Molecular Medicine, Department of Medicine, Karolinska Institutet, Stockholm, Sweden.
- Europace. 2015 May 1; 17 (5): 767-77.
AbstractInfectious complications after cardiac implantable electronic device (CIED) implantation are increasing over time and are associated with substantial mortality and healthcare costs. The aim of this study was to systematically summarize the literature on risk factors for infection after pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy device implantation. Electronic searches (up to January 2014) were performed in PubMed, Scopus, and Web of Science databases. Sixty studies (21 prospective, 9 case-control, and 30 retrospective cohort studies) met the inclusion criteria. The average device infection rate was 1-1.3%. In the meta-analysis, significant host-related risk factors for infection included diabetes mellitus (odds ratio (OR) [95% confidence interval] = 2.08 [1.62-2.67]), end-stage renal disease (OR = 8.73 [3.42-22.31]), chronic obstructive pulmonary disease (OR = 2.95 [1.78-4.90]), corticosteroid use (OR = 3.44 [1.62-7.32]), history of the previous device infection (OR = 7.84 [1.94-31.60]), renal insufficiency (OR = 3.02 [1.38-6.64]), malignancy (OR = 2.23 [1.26-3.95]), heart failure (OR = 1.65 [1.14-2.39]), pre-procedural fever (OR = 4.27 [1.13-16.12]), anticoagulant drug use (OR = 1.59 [1.01-2.48]), and skin disorders (OR = 2.46 [1.04-5.80]). Regarding procedure-related factors, post-operative haematoma (OR = 8.46 [4.01-17.86]), reintervention for lead dislodgement (OR = 6.37 [2.93-13.82]), device replacement/revision (OR = 1.98 [1.46-2.70]), lack of antibiotic prophylaxis (OR = 0.32 [0.18-0.55]), temporary pacing (OR = 2.31 [1.36-3.92]), inexperienced operator (OR = 2.85 [1.23-6.58]), and procedure duration (weighted mean difference = 9.89 [0.52-19.25]) were all predictors of CIED infection. Among device-related characteristics, abdominal pocket (OR = 4.01 [2.48-6.49]), epicardial leads (OR = 8.09 [3.46-18.92]), positioning of two or more leads (OR = 2.02 [1.11-3.69]), and dual-chamber systems (OR = 1.45 [1.02-2.05]) predisposed to device infection. This systematic review on risk factors for CIED infection may contribute to developing better infection control strategies for high-risk patients and can also help risk assessment in the management of device revisions.Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.