-
J Clin Monit Comput · Oct 2017
Comparative StudyObservation of ventilation effects of I-gel™, Supreme™ and Ambu AuraOnce™ with respiratory dynamics monitoring in small children.
- Zhiqing Gu, Quanying Jin, Junjun Liu, and Lianhua Chen.
- Department of Anesthesiology, Shanghai Children's Hospital, Shanghai Jiaotong University, Shanghai, China.
- J Clin Monit Comput. 2017 Oct 1; 31 (5): 1035-1041.
AbstractThe shortcomings of laryngeal mask airway (LMA™), such as upper airway obstruction and gastric distension or airway leakage, may limit its application in small children. The I-gel™ (I-gel), LMA-Supreme™ (LMA-S), and Ambu AuraOnce™ (Ambu) are three improvements upon these shortcomings. This study adopted respiratory dynamic monitoring to observe the ventilation parameters of the three laryngeal masks in small children. A total of 105 children were randomized into Ambu (n = 35), I-gel (n = 35), and LMA-S (n = 35) groups. Primary outcomes included leak pressure and respiratory dynamic data. Secondary outcomes included hemodynamic data and bispectral index values after induction (T0), time after successful laryngeal mask insertion (T1) and at three recording points every 10 min after insertion (T2, T3, and T4), as well as laryngeal mask related adverse reactions. The inspiratory/expiratory tidal volume per kilogram of body weight in the Ambu group was significantly different from those in the other groups (P < 0.05), while the leak pressure in the Ambu group was significantly lower (P < 0.05). At T3 and T4, the expiratory resistance values in the Ambu group were significantly lower than those in the LMA-S group (P < 0.05). We have shown that the three laryngeal masks provided secure ventilation in children <6 years of age by using continuous respiratory dynamic monitoring. We concluded that the I-gel presented a better sealing effect and fewer adverse reactions.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.