• Asian J Neurosurg · Jul 2013

    Percutaneous pedicle screw placement in the thoracic spine: A cadaveric study.

    • Carolyn A Hardin, Shahid M Nimjee, Isaac O Karikari, Abhishek Agrawal, Richard G Fessler, and Robert E Isaacs.
    • Department of Surgery, Division of Neurosurgery, Duke University Medical Center, Durham, NC, USA.
    • Asian J Neurosurg. 2013 Jul 1; 8 (3): 153-6.

    Study DesignA cadaveric study to determine the accuracy of percutaneous screw placement in the thoracic spine using standard fluoroscopic guidance.Summary Of Background DataWhile use of percutaneous pedicle screws in the lumbar spine has increased rapidly, its acceptance in the thoracic spine has been slower. As indications for pedicle screw fixation increase in the thoracic spine so will the need to perform accurate and safe placement of percutaneous screws with or without image navigation. To date, no study has determined the accuracy of percutaneous thoracic pedicle screw placement without use of stereotactic imaging guidance.Materials And MethodsEighty-six thoracic pedicle screw placements were performed in four cadaveric thoracic spines from T1 to T12. At each level, Ferguson anterior-posterior fluoroscopy was used to localize the pedicle and define the entry point. Screw placement was attempted unless the borders of the pedicle could not be delineated solely using intraoperative fluoroscopic guidance. The cadavers were assessed using pre- and postprocedural computed tomography (CT) scans as well as dissected and visually inspected in order to determine the medial breach rate.ResultsNinety pedicles were attempted and 86 screws were placed. CT analysis of screw placement accuracy revealed that only one screw (1.2%) breached the medial aspect of the pedicle by more than 2 mm. A total of four screws (4.7%) were found to have breached medially by visual inspection (three Grade 1 and one Grade 2). One (1.2%) lateral breach was greater than 2 mm and no screw violated the neural foramen. The correlation coefficient of pedicle screw violations and pedicle diameter was found to be 0.96.ConclusionsThis cadaveric study shows that percutaneous pedicle screw placement can be performed in the thoracic spine without a significant increase in the pedicle breach rate as compared with standard open techniques. A small percentage (4.4%) of pedicles, especially high in the thoracic spine, may not be safely visualized.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.