    Multicenter Study

    Predicting arterial blood gas and lactate from central venous blood analysis in critically ill patients: a multicentre, prospective, diagnostic accuracy study.

    • T Boulain, D Garot, P Vignon, J-B Lascarrou, D Benzekri-Lefevre, P-F Dequin, and Clinical Research in Intensive Care and Sepsis (CRICS) Group.
    • Medical-Surgical Intensive Care Unit, Regional Hospital Centre, avenue de l'Hôpital, Orléans F-45067, France thierry.boulain@chr-orleans.fr.
    • Br J Anaesth. 2016 Sep 1; 117 (3): 341-9.

    BackgroundThe estimation of arterial blood gas and lactate from central venous blood analysis and pulse oximetry [Formula: see text] readings has not yet been extensively validated.MethodsIn this multicentre, prospective study performed in 590 patients with acute circulatory failure, we measured blood gases and lactate in simultaneous central venous and arterial blood samples at 6 h intervals during the first 24 h after insertion of central venous and arterial catheters. The study population was randomly divided in a 2:1 ratio into model derivation and validation sets. We derived predictive models of arterial pH, carbon dioxide partial pressure, oxygen saturation, and lactate, using clinical characteristics, [Formula: see text], and central venous blood gas values as predictors, and then tested their performance in the validation set.ResultsIn the validation set, the agreement intervals between predicted and actual values were -0.078/+0.084 units for arterial pH, -1.32/+1.36 kPa for arterial carbon dioxide partial pressure, -5.15/+4.47% for arterial oxygen saturation, and -1.07/+1.05 mmol litre(-1) for arterial lactate (i.e. around two times our predefined clinically tolerable intervals for all variables). This led to ∼5% (or less) of extreme-to-extreme misclassifications, thus giving our predictive models only marginal agreement. Thresholds of predicted variables (as determined from the derivation set) showed high predictive values (consistently >94%), to exclude abnormal arterial values in the validation set.ConclusionsUsing clinical characteristics, [Formula: see text], and central venous blood analysis, we predicted arterial blood gas and lactate values with marginal accuracy in patients with circulatory failure. Further studies are required to establish whether the developed models can be used with acceptable safety.© The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.