• Ulus Travma Acil Cer · Jul 2016

    [Comparison of 90° and 180° plate constructions for comminuted distal humerus fractures in adults, and effects on clinical results].

    • Volkan Eryuva, Taşkın Altay, Cemil Kayalı, Zafer Kement, and Caner Çıtak.
    • Department of Orthopaedics and Traumatology, Trabzon Fatih State Hospital, Trabzon-Turkey.
    • Ulus Travma Acil Cer. 2016 Jul 1; 22 (4): 386-90.

    BackgroundThe present objective was to compare 90° and 180° double-plate constructions for complex distal humerus fractures, as well as to evaluate superiority of construction type.MethodsRetrospectively evaluated were 17 patients treated for type C distal humerus fracture according to AO/ASIF classification between January 2009 and January 2013. All attended minimum 6-month follow-up. Elbow function was assessed with anteroposterior and lateral x-ray, and Mayo elbow performance score evaluation at outpatient clinics.ResultsPatient population included 14 males (82.3%) and 3 females (17.7%). Mean patient age was 40.5 years. According to AO/ASIF distal humerus classification, 3 (17.7%) type C1, 9 (52.9%) type C2, and 5 (29.4%) type C3 fractures were included. Six were open fractures (35.3%). According to Gustilo-Anderson classification, 4 (23.5%) fractures were type 1, and 2 (11.7%) were type 2. Construction performed was 90° in 11 cases (64.7%) and 180° in 6 cases (36.3%). Chevron osteotomy was performed in all cases. Mean follow-up period was 25.6 (6-52) months. Upon final examination, mean elbow flexion was 105º (85º-130º), and mean extension loss was 10º (0º-20º). According to Mayo elbow performance scoring system, 12 (70.5%) results were excellent, and 5 (29.5%) were good. No statistically significant clinical difference was found between 90° and 180° plate construction groups (p=0.169).DiscussionSurgeons should determine the construction type appropriate to individual cases of adult distal humerus type C fractures using preoperative x-rays and intraoperative means. Choice of construction type has particular importance in cases of lateral columnar fracture complexity. If no comminution is present in the lateral column, 90º double-plating leads to satisfactory outcome, while 180º plating leads to satisfactory outcome when comminution is present in the lateral column.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…