• Anesthesia and analgesia · Dec 2016

    Comparative Study Observational Study

    SEER Sonorheometry Versus Rotational Thromboelastometry in Large Volume Blood Loss Spine Surgery.

    • Bhiken I Naik, Marcel E Durieux, Anne Knisely, Juhee Sharma, Vivien C Bui-Huynh, Bhavana Yalamuru, Abdullah S Terkawi, and Edward C Nemergut.
    • From the Departments of *Anesthesiology, †Neurosurgery, University of Virginia, Charlottesville, Virginia; and ‡Department of Anesthesiology, University of Iowa, Iowa City, Iowa.
    • Anesth. Analg. 2016 Dec 1; 123 (6): 1380-1389.

    BackgroundSonic estimation of elasticity via resonance (SEER) sonorheometry is a novel technology that uses acoustic deformation of the developing clot to measure its viscoelastic properties and extract functional measures of coagulation. Multilevel spine surgery is associated with significant perioperative blood loss, and coagulopathy occurs frequently. The aim of this study was to correlate SEER sonorheometry results with those of equivalent rotation thromboelastometry (ROTEM) and laboratory parameters obtained during deformity correction spine surgery.MethodsFour independent SEER sonorheometry hemostatic indices (clot time, clot stiffness, fibrinogen, and platelet contribution) were measured. SEER sonorheometry clot time, using kaolin as an activator, was correlated with ROTEM intrinsic temogram clotting time and the activated partial thromboplastin time. For clot stiffness, thromboplastin was the primary activator, and this was correlated against ROTEM external temogram amplitude at 10 minutes (A10). The assay for the fibrinogen contribution was similar to clot stiffness, but abciximab was added to inhibit platelet function. The fibrinogen contribution assay was correlated with the ROTEM fibrinogen temogram A10. Finally, the SEER sonorheometry platelet contribution was calculated by subtracting the fibrinogen contribution from the clot stiffness. This variable was correlated with both absolute platelet counts, and ROTEM determined clot elasticity attributable to platelets.ResultsFifty-one patients were enrolled in this prospective observational study. SEER sonorheometry clot stiffness, fibrinogen, and platelet contribution had a very strong correlation with ROTEM external temogram A10 (rs = .92; 99% confidence interval, .85-.96), fibrinogen temogram A10 (rs = .90; 99% confidence interval, .83-.93), and ROTEM-determined clot elasticity attributable to platelets (rs = .89; 99% confidence interval, .80-.95). SEER sonorheometry clot time exhibited moderate correlation with ROTEM intrinsic temogram clotting time (rs = .62; 99% confidence interval, .44-.77) and very weak correlation with activated partial thromboplastin time (rs = .33; 99% confidence interval, .10-.51).ConclusionsSEER sonorheometry demonstrates very strong correlation with ROTEM for determining clot stiffness and assessing fibrinogen and platelet contribution to clot strength in major spine surgery. An advantage of SEER sonorheometry is direct measurement of clot elasticity with no need to transform amplitude oscillation to elasticity.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…