• Eur J Anaesthesiol · Dec 2016

    Multicenter Study Comparative Study Observational Study

    Determination of loss of consciousness: a comparison of clinical assessment, bispectral index and electroencephalogram: An observational study.

    • Eva-Lena Zetterlund, Henrik Gréen, Anna Oscarsson, Svante Vikingsson, Magnus Vrethem, Maj-Lis Lindholm, and Christina Eintrei.
    • From the Department of Medical and Health Sciences, Division of Drug Research, Linköping University (E-LZ, HG, AO, SV, CE), Department of Forensic Genetics and Forensic Toxicology, National Board of Forensic Medicine (HG), Department of Clinical and Experimental Medicine, Division of Clinical Neurophysiology, Linköping University (MV), and Department of Anaesthesia and Intensive Care, Linköping University, Kalmar Hospital, Linköping, Sweden (M-LL).
    • Eur J Anaesthesiol. 2016 Dec 1; 33 (12): 922-928.

    BackgroundComputer-processed algorithms of encephalographic signals are widely used to assess the depth of anaesthesia. However, data indicate that the bispectral index (BIS), a processed electroencephalography monitoring system, may not be reliable for assessing the depth of anaesthesia.ObjectiveThe aim of this study was to evaluate the ability of the BIS monitoring system to assess changes in the level of unconsciousness, specifically during the transition from consciousness to unconsciousness, in patients undergoing total intravenous anaesthesia with propofol. We compared BIS with the electroencephalogram (EEG), and clinical loss of consciousness (LOC) defined as loss of verbal commands and eyelash reflex.DesignThis was an observational cohort study.SettingUniversity Hospital Linköping, University Hospital Örebro, Finspång Hospital and Kalmar Hospital, Sweden from October 2011 to April 2013.PatientsA total of 35 ASA I patients aged 18 to 49 years were recruited.InterventionsThe patients underwent total intravenous anaesthesia with propofol and remifentanil for elective day-case surgery. Changes in clinical levels of consciousness were assessed by BIS and compared with assessment of stage 3 neurophysiological activity using the EEG. The plasma concentrations of propofol were measured at clinical LOC and 20 and 30 min after LOC.Main Outcome MeasuresThe primary outcome was measurement of BIS, EEG and clinical LOC.ResultsThe median BIS value at clinical LOC was 38 (IQR 30 to 43), and the BIS values varied greatly between patients. There was no correlation between BIS values and EEG stages at clinical LOC (r = -0.1, P = 0.064). Propofol concentration reached a steady state within 20 min.ConclusionThere was no statistically significant correlation between BIS and EEG at clinical LOC. BIS monitoring may not be a reliable method for determining LOC.Clinical Trials RegistryThis trial was not registered because registration was not mandatory at the time of the trial.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.