BackgroundVentilator-induced dynamic hemodynamic parameters such as stroke volume variation (SVV) and pulse pressure variation (PPV) have been shown to predict fluid responsiveness in contrast to static hemodynamic parameters such as central venous pressure (CVP). We hypothesized that the ventilator-induced central venous pressure variation (CVPV) could predict fluid responsiveness.MethodsTwenty-two elective cardiac surgery patients were studied post-operatively on the intensive care unit during mechanical ventilation with tidal volumes of 6-8 ml/kg without spontaneous breathing efforts or cardiac arrhythmia. Before and after administration of 500mL hydroxyethyl starch, SVV and PPV were measured using pulse contour analysis by modified Modelflow(®) , while CVP was obtained from a central venous catheter positioned in the superior vena cava. CVPV was calculated as 100 × (CVPmax -CVPmin )/[(CVPmax + CVPmin) /2].ResultsNineteen patients (86%) were fluid responders defined as an increase in cardiac output of ≥ 15% after fluid administration. CVPV decreased upon fluid loading in responders, but not in non-responders. Baseline CVP values showed no correlation with a change in cardiac output in contrast to baseline SVV (r = 0.60, P = 0.003), PPV (r = 0.58, P = 0.005), and CVPV (r = 0.63, P = 0.002). Baseline values of SVV > 9% and PPV > 8% could predict fluid responsiveness with a sensitivity of 89% and 95%, respectively, both with a specificity of 100%. Baseline CVPV could identify all fluid responders and non-responders correctly at a cut-off value of 12%. There was no difference between the area under the receiver operating characteristic curves of SVV, PPV, and CVPV.ConclusionThe use of ventilator-induced CVPV could predict fluid responsiveness similar to SVV and PPV in post-operative cardiac surgery patients.© 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.