-
- Paul Celestre, Claire Roberston, Andrew Mahar, Richard Oka, Matthew Meunier, and Alexandra Schwartz.
- Department of Orthopaedic Surgery, University of California - San Diego, San Diego, California, USA.
- J Orthop Trauma. 2008 Apr 1; 22 (4): 241-7.
ObjectivesTo evaluate the biomechanical properties of both plate location (superior versus anterior-inferior) and plate type Small Fragment Contourable Dual Compression Plate (CDCP) versus 3.5 mm Universal Locking System Contourable Dual Compression Plate (Locked CDCP) in a synthetic midshaft transverse clavicle fracture model.MethodsTwenty-four pre-osteomized synthetic clavicles were repaired with either CDCP or locked CDCP technology 3.5 mm plates in either the superior or anterior-inferior position to form 4 groups of 6 clavicles. These were subsequently tested to evaluate torsional and axial construct stiffness, as well as bending load to failure, bending failure stiffness, and method of failure.ResultsIn axial compression, locked CDCP constructs were significantly more stiff than CDCP constructs (p < 0.001), but no statistically significant effect of plate location was observed. Torsional tests demonstrated a significant 2-way interaction favoring locked CDCP plates in the superior position and standard CDCP plates in the anterior-inferior position (p < 0.001). Bending failure testing revealed that the superior plate location had higher load to failure and bending failure stiffness than the anterior-inferior location (p < 0.0001). In addition, the superior locked CDCP plates demonstrated significantly greater bending failure stiffness than superior CDCP plates (p < 0.0001).ConclusionsBiomechanically, repairing a midshaft clavicle fracture with a superior plate was more favorable compared to anterior-inferior plating in terms of both load to failure and bending failure stiffness. Furthermore, superior locked CDCP plates show improved bending failure stiffness over superior CDCP plates.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.