- Rodolfo Gebhardt, Michelle Ludwig, Steve Kirsner, Kelly Kisling, and Alyssa K Kosturakis.
- Departments of Pain, MDACC, Houston, TX 77030, USA. rgebhardt@mdanderson.org
- Pain Med. 2013 Mar 1;14(3):398-402.
PurposeRadiotherapy affects the functioning of pacemakers. Guidelines based on dosimetric data exist regarding tolerable doses to pacemakers. Little is known about the effects of radiation on implantable drug delivery systems (IDDS). The objective of our study is to evaluate the safety of radiation treatment delivered to patients with IDDS.Methods And MaterialsWe evaluated patients who received external beam radiation therapy in our department after implantation of an IDDS between January 1, 2000 and November 30, 2011. Information was collected on IDDS function, treatment goals, treatment fields, prescribed doses, treatment energies, and cumulative radiation doses to the pump and the catheter.ResultsA total of 39 patients received 60 separate courses of radiation therapy, of which 12 patients received radiation with either the pump or the catheter in the field. The remaining patients received scatter radiation only. The goal of radiation was palliative in all but one of the patients. Cumulative pump doses ranged from 5 to 36 Gy, and catheter doses ranged from 15 to 45 Gy. Beam energies ranged from 6 to 18 MV photons. All devices were checked after the completion of radiotherapy with a median follow-up of 4.5 months, and all were found to be in good working condition.ConclusionsIDDS failures related to external beam radiation therapy seem to represent a rare occurrence. While we do not see reason to limit radiotherapy in patients with IDDS, we recommend device check after the completion of radiotherapy as well as if the patient has an increase in pain or analgesic requirement.Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.