Multicenter Study
Initial Technical Experience with the SMART Coil for the Embolization of Intracranial Aneurysms.
- Alejandro M Spiotta, Kyle M Fargen, Jonathan Lena, Imran Chaudry, Raymond D Turner, Aquilla S Turk, Daniel Huddle, David Loy, Richard Bellon, and Donald Frei.
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA. Electronic address: spiotta@musc.edu.
- World Neurosurg. 2017 Jan 1; 97: 80-85.
Background/ObjectiveTraditional platinum coils used for cerebral aneurysm embolization have a uniform degree of softness throughout an individual coil's length. Recently, SMART Coils (Penumbra Inc., Alameda, California, USA) have been developed, which transition in softness along the length of their coils. We report the initial clinical results with this technology.MethodsA retrospective study of all patients undergoing aneurysm coiling with SMART Coils at 2 centers was performed to evaluate the safety and efficacy of this new technology. Outcome and angiographic data were self-reported by individual treatment centers.ResultsFifty-nine patients underwent treatment for cerebral aneurysms with SMART Coils (44% in the setting of subarachnoid hemorrhage). Mean aneurysm size was 5.9 ± 2 mm × 4.5 ± 2 mm. Mean neck size was 3.4 ± 1 mm. More than half (54.2%) of the patients underwent coiling exclusively with SMART Coils. The remainder used either framing or finishing coils of another type. About one third (33.9%) underwent balloon-assisted coiling, and 47.5% underwent stent-assisted coiling. There were no device malfunctions in any of the patients. Six (10.1%) minor complications without clinical sequelae occurred. Raymond I or II occlusion was achieved in 71.2%.ConclusionsOur results demonstrate adequate device safety in a variety of both ruptured and unruptured aneurysm locations. This design enables progressive changes in softness along the length of an individual coil, which offers several potential advantages in the clinical use. This initial investigation of SMART Coil technology demonstrates safety and efficacy in the treatment of a wide range of aneurysm sizes, locations, and morphologies in both ruptured and unruptured settings.Copyright © 2016 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.