Interact Cardiovasc Thorac Surg · Apr 2015
Hybrid branch pulmonary artery stent placement in adults with congenital heart disease.
- Winston Lynch, S Mathijs Boekholdt, Mark G Hazekamp, Robbert J de Winter, and David R Koolbergen.
- Department of Cardiothoracic Surgery, Academic Medical Centre, Amsterdam, Netherlands.
- Interact Cardiovasc Thorac Surg. 2015 Apr 1; 20 (4): 499-503.
ObjectivesValuable treatment modalities for branch pulmonary artery (BPA) stenoses are surgical patch angioplasty, percutaneous BPA stenting and hybrid stent placement. The purpose of this study was to report our institutional experience with hybrid stent placement to relieve BPA stenoses.MethodsBetween August 2007 and May 2014, 7 adults (5 females) with congenital heart disease (CHD) had elective intraoperative BPA stent placement. All 7 patients had undergone previous surgery [6 tetralogy of Fallot repairs and 1 arterial switch operation for transposition of the great arteries (TGAs)]. A total of 7 stents (4 right pulmonary artery, 3 left pulmonary artery) were implanted under direct vision, concomitant with a pulmonary homograft implantation (tetralogy of Fallot patients), or because percutaneous stenting was not feasible (TGA patient). Retrospective analysis of clinical data, procedural details and outcomes was performed.ResultsOverall, the mean age was 35 ± 7.2 years. Stent implantation was successful in all procedures. The mean postinflation stent diameter was 13.3 ± 2.0 mm. No stent migration, fracture, stent thrombosis, reintervention or deaths occurred. In 1 case the procedure was complicated by a right pulmonary artery tear just distal to the stent which was repaired by surgical patch angioplasty. At a mean follow-up of 55.6 ± 26 months no patient required catheter reintervention or surgery. Echocardiography (mean follow-up 47.1 ± 22 months), MRI (mean follow-up 43.8 ± 37 months) and CT data (mean follow-up 14.8 ± 10 months) demonstrate a BPA diameter increment from a mean 5.57 ± 2.29 to 10.71 ± 2.56 mm.ConclusionsHybrid intraoperative BPA stent placement is safe and effective and can be used as an alternative for surgical patch angioplasty or if percutaneous BPA stenting is not feasible. Short- to mid-term results are good.© The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.