    Towards physiological ankle movements with the ActiGait implantable drop foot stimulator in chronic stroke.

    • Jennifer Ernst, Jessica Grundey, Manuel Hewitt, Friederike von Lewinski, Jürgen Kaus, Thomas Schmalz, Veit Rohde, and David Liebetanz.
    • Department of Clinical Neurophysiology, University Medical Center Göttingen, 37075 Göttingen, Germany.
    • Restor. Neurol. Neurosci. 2013 Jan 1; 31 (5): 557-69.

    PurposeFunctional electrical stimulation represents an alternative to conventional and passive ankle foot orthosis (AFO) for the treatment of stroke-related drop foot. We evaluated the implantable 4-channel stimulator ActiGait, which selectively and directly stimulates the peroneal nerve. In addition, it bypasses the need for surface electrodes and cables.MethodsWalking speed (10-meter gait test, [m/s]) and walking endurance (6-minute gait test [m/6min]) of 5 patients were tested prior to, as well as 6 and 12 weeks after, the implantation of the ActiGait implantable drop foot stimulator system. In addition, ankle joint angles were assessed during specific phases of the gait cycle, i.e. initiation angle (IA) at the first contact of the foot to the floor, initial plantar flexion (IPF), dorsiflexion (DF) and final plantar flexion (FPF) in [°] during stance phase. The ankle joint angles were measured at baseline and 12 weeks after ActiGait implantation.ResultsAt the first follow-up, patients' gait speed was found to have increased (0.55; 0.77 m/s) as had walking endurance (211; 260 m). Improvement in gait speed (0.55; 0.77 m/s) and endurance (214; 248 m) was still present after 12 weeks. In addition, gait analysis after 12 weeks revealed a nearly normal physiological initiation angle (113° vs 122°) and an increase in the initial plantar flexion (7° vs. 0°). The initiation angle (IA) represents a well-suited parameter for adequate pre-positioning of the foot at the beginning of the stance phase and is necessary to prevent stumbling and falling. Furthermore, IA is identical to the maximum achieved dorsiflexion during the swing phase of gait. Thus, analysis of the IA of subjects walking with the implantable drop foot stimulator systems ActiGait is particularly useful in showing that the implantable system restores the IA towards physiological ankle movements.ConclusionThe ActiGait system increased gait speed, walking endurance and the physiology of important ankle joint kinematics. This is most likely a result of ankle dorsiflexion by active peroneal stimulation during the swing phase of gait and optimized prepositioning (IA) of the foot at the beginning of stance phase. The ActiGait system represents a therapeutic option for the treatment of patients suffering drop foot due to a cerebrovascular insult.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…