-
J Spinal Disord Tech · Dec 2012
Comparative StudyComparison of a fluoroscopic 3-dimensional imaging system and conventional CT in detection of pars fractures in the cadaveric lumbar spine.
- Christopher K Kepler, Helene Pavlov, Richard J Herzog, Bernard A Rawlins, Yoshimi Endo, and Daniel W Green.
- Department of Orthopaedic Surgery, Surgery, Spine and Scoliosis Service, Hospital for Special Surgery, NY 10021, USA. chris.kepler@gmail.com
- J Spinal Disord Tech. 2012 Dec 1; 25 (8): 429-32.
Study DesignCadaveric Study.ObjectiveTo compare a fluoroscopic imaging system with computed tomography (CT) and radiographs in detection of spondylolysis and radiation exposure in a cadaver model.Summary Of Background DataLumbar spondylolysis is defined as a defect or fracture of the pars interarticularis and occurs with or without anterior spondylolisthesis. CT scan is the gold standard imaging study for spondylolysis but is limited by the supine position, which may cause reduction of anterolisthesis and by ionizing radiation, which limits the frequency of follow-up scans.MethodsThirteen intact cadaveric lumbar spine segments with 26 pars were randomized to be left intact or to undergo simulated fracture using a 1.3 mm oscillating microsurgical saw. Fifteen pars underwent simulated fracture and 11 pars were left intact. Lumbar spine segments were imaged using plain radiographs, multiplanar fluoroscopic imaging, and conventional CT scan. The images were interpreted by 3 observers blinded to the number and location of defects. Radiation exposure and doses were recorded from all imaging units.ResultsAverage radiation doses were 0.0025 mSv for each radiograph, 0.23 mSv (low dose) and 0.47 mSv (high dose) for fluoroscopic imaging, and 1.5 mSv for conventional CT imaging (pediatric dose setting). Evaluation of radiographs for spondylolysis had sensitivity of 98% and specificity of 97%. Evaluation using low-dose fluoroscopic images, high-dose fluoroscopic images, and CT scan images correctly identified the status of all pars based on multiplanar images; sensitivity and specificity were 100%. Kappa analysis demonstrated a value of 0.89 for radiographic interpretation indicating excellent agreement. Kappa values describing agreement for image interpretation for fluoroscopic imaging and CT scan were equal to 1.0, representing perfect agreement.ConclusionsThree-dimensional fluoroscopic imaging provides comparable diagnostic imaging with CT scan in an experimental cadaveric model of spondylolysis using up to 85% less radiation than conventional CT scan.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.