-
Scand J Trauma Resus · Oct 2016
ReviewA systematic review on the rotational thrombelastometry (ROTEM®) values for the diagnosis of coagulopathy, prediction and guidance of blood transfusion and prediction of mortality in trauma patients.
- Precilla V Veigas, Jeannie Callum, Sandro Rizoli, Bartolomeu Nascimento, and Luis Teodoro da Luz.
- Department of Surgery, St. Michael's Hospital and Institute of Medical Science, University of Toronto, 30 Bond Street, 3074 Donnelly Wing, Toronto, M5W 1B8, ON, Canada.
- Scand J Trauma Resus. 2016 Oct 3; 24 (1): 114.
IntroductionViscoelastic assays have been promoted as an improvement over traditional coagulation tests in the management of trauma patients. Rotational thromboelastometry (ROTEM®) has been used to diagnose coagulopathy and guide hemostatic therapy in trauma. This systematic review of clinical studies in trauma investigates the ROTEM® parameters thresholds used for the diagnosing coagulopathy, predicting and guiding transfusion and predicting mortality.MethodsSystematic literature search was performed using MEDLINE, EMBASE and Cochrane databases. We included studies without restricting year of publication, language or geographic location. Original studies reporting the thresholds of ROTEM® parameters in the diagnosis or management of coagulopathy in trauma patients were included. Data on patient demographics, measures of coagulopathy, transfusion and mortality were extracted. We reported our findings according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Quality assessment and risk of bias were performed using Newcastle Ottawa Scale (NOS) and the quality assessment of diagnostic accuracy studies (QUADAS-2) tools, respectively.ResultsA total of 13 observational studies involving 2835 adult trauma patients met the inclusion criteria. Nine studies were prospective and four were retrospective. There were no randomized controlled trials. The quality of the included studies was moderate (mean NOS 5.92, standard deviation 0.26). Using QUADAS-2, only 1 study (7.6 %) had low risk of bias in all domains, and 9 studies (69.2 %) had low risk of applicability concerns. Outcomes from 13 studies were grouped into three categories: diagnosis of coagulopathy (n = 10), prediction of massive transfusion or transfusion guidance (n = 6) and prediction of mortality (n = 6). Overall, specific ROTEM® parameters measured (clot amplitude and lysis) in the extrinsically activated test (EXTEM) and the fibrin-based extrinsically activated test (FIBTEM) were consistently associated with the diagnosis of coagulopathy, increased risk of bleeding and massive transfusion, and prediction of mortality. Presence of hyperfibrinolysis by ROTEM® was associated with increased mortality.ConclusionsMost of the evidence indicates that abnormal EXTEM and FIBTEM clot amplitude (CA5, CA10) or maximal clot firmness (MCF) diagnose coagulopathy, and predict blood transfusion and mortality. The presence of fibrinolysis (abnormal lysis index [LI30] or maximum lysis [ML]) was also associated with mortality. ROTEM® thus, may be of value in the early management of trauma patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.