- Michiel W P de Wolf, Reiner Gottschall, Niels P Preussler, Markus Paxian, and Dietmar Enk.
- Department of Anesthesiology and Pain Therapy, Maastricht University Medical Center, PO Box 5800, Maastricht, AZ, 6202, The Netherlands. m.de.wolf@mumc.nl.
- Can J Anaesth. 2017 Jan 1; 64 (1): 37-44.
PurposeDuring difficult airway management, oxygen insufflation through airway-exchange and intubating catheters (AEC/IC) can lead to life-threatening hyperinflation. Ventrain(®) was originally designed to facilitate emergency ventilation using active expiration through short, small-bore cannulas. Herein, we studied its efficacy (oxygenation and ventilation) and safety (avoidance of hyperinflation) in a long, small-bore AEC.MethodsIn six anesthetized pigs, the upper airway was obstructed, except for a 100 cm long, 3 mm internal diameter AEC. After apneic desaturation to a peripheral oxygen saturation (SpO2) of < 70%, ventilation through the AEC was started with Ventrain at an oxygen flow of 15 L·min(-1), a frequency of 30 breaths·min(-1), and an inspiration/expiration ratio of approximately 1:1. It was continued for ten minutes.ResultsWithin one minute, severe hypoxia was reversed from a median [interquartile range] arterial saturation (SaO2) of 48 [34-56] % before initiation of Ventrain ventilation to 100 [99-100] % afterward (median difference 54%; 95% confidence interval [CI] 44 to 67; P = 0.028). In addition, hypercarbia was reversed from PaCO2 of 59 [53-61] mmHg to 40 [38-42] mmHg (median difference of -18 mmHg; 95% CI -21 to -15; P = 0.028). After ten minutes of Ventrain use, peak inspiratory and end-expiratory pressures were lower than during baseline pressure-controlled ventilation (8 [7-9] mmHg vs 12 [10-14] mmHg and -2 [-3 to +1] mmHg vs 4 [2 to 4] mmHg, respectively; P = 0.027 for both). No hemodynamic deterioration occurred.ConclusionVentrain provides rapid reoxygenation and effective ventilation through a small-bore AEC in pigs with an obstructed airway. In clinical emergency situations of obstructed airways, this device may be able to overcome problems of unintentional hyperinflation and high intrapulmonary pressures when ventilating through long, small-bore catheters and could therefore minimize the risks of barotrauma and hemodynamic instability.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.