-
Intensive care medicine · Apr 2002
Comparative StudyComparison of different methods for measuring intra-abdominal pressure.
- F F Gudmundsson, A Viste, H Gislason, and K Svanes.
- Surgical Research Laboratory, Haukeland University Hospital, University of Bergen, 5021 Bergen, Norway. ffgu@haukeland.no
- Intensive Care Med. 2002 Apr 1; 28 (4): 509-14.
ObjectiveIntra-abdominal pressure (IAP) can be measured in different ways but is usually measured indirectly via the urinary bladder. The aim of the study was to: 1) compare urinary bladder pressure, femoral vein pressure, and inferior caval vein pressure with IAP at different levels of IAP; and 2) try to find an optimal amount of fluid to be instilled into the urinary bladder before measurement of the bladder pressure, and to compare changes in blood flow in the femoral vein with that in the caval vein at different pressure levels.DesignExperimental study.SettingAnimal research laboratory.SubjectsEight domestic swine of both sexes, weighing 30.6+/-2.9 kg (mean+/-SD).InterventionsCatheters connected to pressure transducers were placed into the urinary bladder, the inferior caval vein, the femoral vein, and the superior caval vein. Transit time flow probes were placed around the inferior caval vein and the femoral vein. After a stabilizing period, the abdominal pressure was increased stepwise by instillation of Ringer's solution into the abdomen and then decreased. Thereafter, we instilled fluid into the bladder at an IAP of 8 mmHg and at 20 mmHg and measured the amount of fluid needed to elevate the intra-vesical pressure by 2 mmHg.ResultsThe pressures recorded in the urinary bladder, the inferior caval vein, and the femoral vein reflected the pressure in the abdominal cavity very well. The fluid volume needed to increase the bladder pressure by 2 mmHg was significantly lower at 20 mmHg IAP than at 8 mmHg. Blood flow in the femoral vein and the inferior caval vein showed a similar pattern and decreased when the intra-abdominal pressure increased.ConclusionsIn our porcine model, and increasing the IAP by means of instillation of Ringer's solution, a reliable estimation of the IAP was obtained by measuring the pressure in the urinary bladder, the femoral vein or the inferior caval vein. The IAP estimated indirectly as the urinary bladder pressure is affected by the amount of fluid in the bladder, which should not exceed 10-15 ml. The decrease in femoral vein blood flow reflects the changes in inferior caval vein flow during increased IAP.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.