    Stimulus-evoked EMG monitoring during minimally invasive transpedicular implantation of screws in the lumbosacral spine - Threshold value, methodology and clinical effectiveness.

    • Yunfen Wu and Alfonso Vázquez-Barquero.
    • Department of Intraoperative Neurophysiology, Mount Sinai West Hospital, New York, New York, USA; University of Cantabria, Santander, Cantabria, Spain. Electronic address: yfenwufriendship@gmail.com.
    • World Neurosurg. 2017 Feb 1; 98: 146-151.

    BackgroundStimulus-evoked electromyography (EMG) has been developed to increase the safety of transpedicular placement of screws. There is more consensus about this monitoring method in open surgery. Alarm thresholds for minimally invasive surgery are based on referential value for open surgery. Nevertheless, there are no uniform alarm criteria on this modality for minimally invasive surgery. Using an analysis of alarm threshold, methodology and clinical effectiveness on stimulus-evoked EMG monitoring for minimally invasive transpedicular implantation of screws in the lumbosacral spine, this study aims to reflect and recommend for optimizing accuracy.MethodsUsing a selection of studies, an analysis of the pedicle breach rates and breach-related clinical complication rates was made between studies on minimally invasive surgery by applying different thresholds. A second analysis of the pedicle breach rates and breach-related clinical complication rates was made between studies on open and minimally invasive surgery by applying the same threshold.ResultsIn minimally invasive surgery, stimulus-evoked EMG has an acceptable accuracy in the detection of clinical relevant pedicle breaches. Suction limitation may alter the stimulation threshold. No significant differences in clinical effectiveness were observed between studies by applying thresholds of 5 mA, 7 mA, and 12 mA. However, a low threshold of 5 mA seems inappropriate for the tap stimulation.ConclusionIn minimally invasive surgery, continuous stimulation of instrumentation devices is recommended. A minimum 5-mA threshold should be used for stimulation of the pedicle access needle. Use of higher-stimulation thresholds during tapping and incorporation of an adapted continuous suction system may optimize the accuracy of stimulus-evoked EMG.Copyright © 2016 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.