• Journal of neurosurgery · Oct 2017

    Comparative Study

    Accuracy of 320-detector row nonsubtracted and subtracted volume CT angiography in evaluating small cerebral aneurysms.

    • Wenhua Chen, Wei Xing, Zhongming He, Ya Peng, Caoye Wang, and Qi Wang.
    • Departments of 1 Interventional Radiology.
    • J. Neurosurg. 2017 Oct 1; 127 (4): 725-731.

    AbstractOBJECTIVE The study aimed to assess the diagnostic accuracy of 320-detector row nonsubtracted and subtracted volume CT angiography (VCTA) in detecting small cerebral aneurysms (< 3 mm) compared with 3D digital subtraction angiography (3D DSA). METHODS Six hundred sixty-two patients underwent 320-detector row VCTA and 3D DSA for suspected cerebral aneurysms. Five neuroradiologists independently reviewed VCTA and 3D DSA images. The 3D DSA was considered the reference standard, and the sensitivity, specificity, and accuracy of nonsubtracted and subtracted VCTA in depicting small aneurysms were analyzed. A p value < 0.05 was considered a significant difference. RESULTS According to 3D DSA images, 98 small cerebral aneurysms were identified in 90 of 662 patients. Nonsubtracted VCTA depicted 90 small aneurysms. Ten small aneurysms were missed, and 2 small aneurysms were misdiagnosed. The missed small aneurysms were located almost in the internal carotid artery, near bone tissue. The sensitivity, specificity, and accuracy of nonsubtracted VCTA in depicting small aneurysms were 89.8%, 99.2%, and 96.5%, respectively, on a per-aneurysm basis. Subtracted VCTA depicted 97 small aneurysms. Three small aneurysms were missed, and 2 small aneurysms were misdiagnosed. The sensitivity, specificity, and accuracy of subtracted VCTA in depicting small aneurysms were 96.9%, 99.2%, and 98.6%, respectively, on a per-aneurysm basis. There was no difference in accuracy between subtracted VCTA and 3D DSA (p = 1.000). However, nonsubtracted VCTA had significantly less sensitivity than 3D DSA and subtracted VCTA (p = 0.039 and 0.016, respectively). CONCLUSIONS Subtracted 320-detector row VCTA is sensitive enough to replace 3D DSA in the diagnosis of small cerebral aneurysms (< 3 mm). The accuracy rate of nonsubtracted VCTA was lower than that of subtracted VCTA and 3D DSA, especially in the assessment of small internal carotid artery aneurysms adjacent to the skull base.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.