-
Observational Study
Cervical Interlaminar Epidural Injections at High Doses Do Not Increase Optic Nerve Sheath Diameter on a Long-Term Basis.
- Hyunzu Kim, Joo Hyeon O, Sung-Jun Hong, Keun Man Shin, JungChan Park, and Sang Soo Kang.
- Department of Anesthesiology and Pain Medicine, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, 445, Gil-dong, Gangdong-gu, Seoul, Korea.
- Pain Physician. 2016 Nov 1; 19 (8): E1173-E1179.
BackgroundCervical epidural injection (CEI) is widely performed on patients with pain originating from the cervical spine. Studies have shown a good relationship between the optic nerve sheath diameter (ONSD) and the intracranial pressure (ICP).ObjectiveThe aim of this study was to evaluate the changes in the ONSD as a non-invasive surrogate marker of ICP after CEI.Study DesignProspective observational study.SettingHospital and ambulatory pain clinic.MethodsTwenty patients undergoing CEI at the C5-6 level were enrolled in this observational study. The CEIs were performed using a total of 14 mL of mixture volume via the interlaminar approach in the right lateral decubitus position. The ONSD through ultrasonography was measured in the initial supine position (T0, baseline), 30 seconds after the completion of CEI (T0.5), at 30-second intervals for 5 minutes (T0.5~T5), and at one-minute intervals for 5 minutes (T6~T10).ResultsThe values of the baseline ONSD (T0) in both eyes were 4.1 ± 0.4 mm. The ONSD significantly increased from T1 to T10 (P < 0.05) compared with T0. The maximum value of the ONSD was measured as 5.1 ± 0.4 mm at T4, and the mean difference between the baseline ONSD and its maximum value was 1.0 mm, which represented about 27%. There was no increase in ICP-related complications such as dizziness, headache, visual acuity, or retinal hemorrhage.LimitationsThis was an observational study without a control group. All patients were presumed to have no intracranial pathology.ConclusionThe 14 mL CEI resulted in an increase in the ONSD by ultrasonography over time. The most critical increase in ONSD was observed 4 minutes after CEI, but this increase was not sustained. Further work is needed to confirm the effects of the speed and volume of the injection and of the position.RegistrationRegistered in the Clinical Research Information Service of the Korea National Institute of Health, registration number: KCT0001487. Key words: Analgesic techniques, epidural block, intracranial pressure, optic nerve sheath diameter, ultrasonography Analgesic techniques, epidural block, intracranial pressure, optic nerve sheath diameter, ultrasonography.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.