ObjectivesStroke volume variation and pulse pressure variation do not reliably predict fluid responsiveness during low tidal volume ventilation. We hypothesized that with transient increase in tidal volume from 6 to 8 mL/kg predicted body weight, that is, "tidal volume challenge," the changes in pulse pressure variation and stroke volume variation will predict fluid responsiveness.DesignProspective, single-arm study.SettingMedical-surgical ICU in a university hospital.PatientsAdult patients with acute circulatory failure, having continuous cardiac output monitoring, and receiving controlled low tidal volume ventilation.InterventionsThe pulse pressure variation, stroke volume variation, and cardiac index were recorded at tidal volume 6 mL/kg predicted body weight and 1 minute after the "tidal volume challenge." The tidal volume was reduced back to 6 mL/kg predicted body weight, and a fluid bolus was given to identify fluid responders (increase in cardiac index > 15%). The end-expiratory occlusion test was performed at tidal volumes 6 and 8 mL/kg predicted body weight and after reducing tidal volume back to 6 mL/kg predicted body weight.ResultsThirty measurements were obtained in 20 patients. The absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight predicted fluid responsiveness with areas under the receiver operating characteristic curves (with 95% CIs) being 0.99 (0.98-1.00) and 0.97 (0.92-1.00), respectively. The best cutoff values of the absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight were 3.5% and 2.5%, respectively. The pulse pressure variation, stroke volume variation, central venous pressure, and end-expiratory occlusion test obtained during tidal volume 6 mL/kg predicted body weight did not predict fluid responsiveness.ConclusionsThe changes in pulse pressure variation or stroke volume variation obtained by transiently increasing tidal volume (tidal volume challenge) are superior to pulse pressure variation and stroke volume variation in predicting fluid responsiveness during low tidal volume ventilation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.