• Lancet · Oct 2015

    Case Reports Multicenter Study

    First clinical use of a bioprosthetic total artificial heart: report of two cases.

    • Alain Carpentier, Christian Latrémouille, Bernard Cholley, David M Smadja, Jean-Christian Roussel, Elodie Boissier, Jean-Noël Trochu, Jean-Pierre Gueffet, Michèle Treillot, Philippe Bizouarn, Denis Méléard, Marie-Fazia Boughenou, Olivier Ponzio, Marc Grimmé, Antoine Capel, Piet Jansen, Albert Hagège, Michel Desnos, Jean-Noël Fabiani, and Daniel Duveau.
    • Department of Cardiovascular Surgery, Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris, Université Paris Descartes-Sorbonne Paris Cité, Paris, France. Electronic address: alain.carpentier@egp.aphp.fr.
    • Lancet. 2015 Oct 17;386(10003):1556-63.

    BackgroundThe development of artificial hearts in patients with end-stage heart disease have been confronted with the major issues of thromboembolism or haemorrhage. Since valvular bioprostheses are associated with a low incidence of these complications, we decided to use bioprosthetic materials in the construction of a novel artificial heart (C-TAH). We report here the device characteristics and its first clinical applications in two patients with end-stage dilated cardiomyopathy. The aim of the study was to evaluate safety and feasibility of the CARMAT TAH for patients at imminent risk of death from biventricular heart failure and not eligible for transplant.MethodsThe C-TAH is an implantable electro-hydraulically actuated pulsatile biventricular pump. All components, batteries excepted, are embodied in a single device positioned in the pericardial sac after excision of the native ventricles. We selected patients admitted to hospital who were at imminent risk of death, having irreversible biventricular failure, and not eligible for heart transplantation, from three cardiac surgery centres in France.FindingsThe C-TAH was implanted in two male patients. Patient 1, aged 76 years, had the C-TAH implantation on Dec 18, 2013; patient 2, aged 68 years, had the implantation on Aug 5, 2014. The cardiopulmonary bypass times for C-TAH implantation were 170 min for patient 1 and 157 min for patient 2. Both patients were extubated within the first 12 postoperative hours and had a rapid recovery of their respiratory and circulatory functions as well as a normal mental status. Patient 1 presented with a tamponade on day 23 requiring re-intervention. Postoperative bleeding disorders prompted anticoagulant discontinuation. The C-TAH functioned well with a cardiac output of 4·8-5·8 L/min. On day 74, the patient died due to a device failure. Autopsy did not detect any relevant thrombus formation within the bioprosthesis nor the different organs, despite a 50-day anticoagulant-free period. Patient 2 experienced a transient period of renal failure and a pericardial effusion requiring drainage, but otherwise uneventful postoperative course. He was discharged from the hospital on day 150 after surgery with a wearable system without technical assistance. After 4 months at home, the patient suffered low cardiac output. A change of C-TAH was attempted but the patient died of multiorgan failure.InterpretationThis preliminary experience could represent an important contribution to the development of total artificial hearts using bioprosthetic materials.FundingCARMAT SA.Copyright © 2015 Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.