• Platelets · Jan 2013

    Sample transport by pneumatic tube system alters results of multiple electrode aggregometry but not rotational thromboelastometry.

    • Michael Glas, Dietmar Mauer, Hazim Kassas, Thomas Volk, and Sascha Kreuer.
    • Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Hospital , Kirrberger Strasse, D-66421 Homburg (Saar) , Germany. michael.glas@uks.eu
    • Platelets. 2013 Jan 1; 24 (6): 454-61.

    AbstractPneumatic tube systems (PTS) present a convenient way for blood sample transport in medical facilities. Associated preanalytical interference in various tests is largely unknown. Implementing point-of-care coagulation management at our institution, we investigated multiple electrode aggregometry (MEA) and rotational thromboelastometry (ROTEM) after PTS transportation. Whole blood samples from patients undergoing general or trauma surgery were analysed by MEA after collection (baseline, '0 × PTS') and sent on a predefined PTS track (n = 12). MEA was repeated after samples travelled the track 4 ('4 × PTS'), 8 ('8 × PTS') and 12 times ('12 × PTS') and compared with stationary controls analysed at the same time. Samples for ROTEM (n = 6) were analysed after collection and travelling the track 12 times. An acceleration detector recorded g-forces on the PTS track. At '0 × PTS' no significant differences in MEA results were detected. Values were significantly lower for transported samples compared with controls ('4 × PTS' to '12 × PTS', p < 0.001). Furthermore, MEA results of PTS samples were significantly decreased for '4 × PTS' to '12 × PTS' compared to baseline (p < 0.001). Except for the clotting time in EXTEM PTS transport did not significantly alter results for investigated ROTEM parameters, compared with baseline and stationary controls. Acceleration detector readout revealed alternating g-forces between -6.3 and +5.9 during transport. PTS transport caused invalid results in MEA while only one ROTEM parameter was found to be affected in this study. Variable acceleration during transport provides a potential reason for platelet activation. The authors recommend sample transport by hand or the device to be placed patient-side when MEA is performed.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…