• Respiratory care · Jan 2017

    Redesign of an Open-System Oxygen Face Mask With Mainstream Capnometer for Children.

    • Natalie Napolitano, Akira Nishisaki, Hayley S Buffman, Jessica Leffelman, Matthew R Maltese, and Vinay M Nadkarni.
    • Respiratory Therapy Department naplitanon@email.chop.edu.
    • Respir Care. 2017 Jan 1; 62 (1): 70-77.

    BackgroundPartial pressure of end-tidal carbon dioxide (PETCO2 ) monitoring in children is important to detect apnea or hypopnea early to intervene before hypoxemia develops. Monitoring PETCO2 in children without a tracheal tube is challenging. To improve PETCO2 measurement accuracy in a commercially available mask with a mainstream CO2 detector, we implemented design changes with deform-and-hold shaping technology and anterior-posterior adjustment of the expiratory gas flow cup.MethodsTwo sizes of redesigned face masks (small for 7-20 kg, medium for 10-40 kg) were evaluated. Initial bench testing used a simulator modeling a spontaneously breathing infant and child with a natural airway. An infant/child manikin head was connected to the breathing lung simulator. A mass flow controller provided expiratory CO2. Mask fit was then evaluated on healthy human subjects to identify anatomical features associated with good fit, defined as square shape capnography waveform during expiration. A 3-dimensional digital scan was used to quantify anatomical features. The gaps between face mask rims and facial surface were manually measured.ResultsBench testing revealed a PETCO2 difference of 3.4 ± 1.5 mm Hg between a measured PETCO2 by the redesigned mask and CO2 concentration at trachea, as compared with 6.7 ± 6.2 mm Hg between PETCO2 measured by nasal cannula and trachea (P < .001). In the human mask fit study, 35 children (13 ± 4 kg) with the small mask and 38 (24 ± 8 kg) with the medium mask were evaluated. Capnography tracing was successfully obtained in 86% of the small and 100% of the medium masks. In children with small-size masks, the gap between the face mask rim and the child's face was not statistically different among those with good mask fit and without (1.0 ± 1.5 mm vs 1.4 ± 1.9 mm, P = .73).ConclusionsPETCO2 measurement by a redesigned open-system face mask with a mainstream CO2 detector was accurate in the bench setting. The redesigned face mask can attain good mask fit and accurate capnography tracings in the majority of infants and children.Copyright © 2017 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…