• Respiratory care · Jan 2017

    Comparative Study

    A Comparison of Different Techniques for Interfacing Capnography With Adult and Pediatric Supplemental Oxygen Masks.

    • Justin S Phillips, Lance P Pangilinan, Earl R E Mangalindan, Joseph L Booze, and Richard H Kallet.
    • Respiratory Care Services, Department of Anesthesia and Perioperative Care, University of California, San Francisco at Zuckerberg San Francisco General Hospital, San Francisco, California. Justin.Phillips@ucsf.edu.
    • Respir Care. 2017 Jan 1; 62 (1): 78-85.

    BackgroundAccurately measuring the partial pressure of end-tidal CO2 (PETCO2 ) in non-intubated patients is problematic due to dilution of expired CO2 at high O2 flows and mask designs that may either cause CO2 rebreathing or inadequately capture expired CO2. We evaluated the performance of 2 capnographic O2 masks (Cap-ONE and OxyMask) against a clinically expedient method using a standard O2 mask with a flow-directed nasal cannula used for capnography (CapnoLine) in a spontaneous breathing model of an adult and child under conditions of normal ventilation, hypoventilation, and hyperventilation.MethodsAn ASL-5000 simulator was attached to a manikin face with a catheter port, through which various CO2/air mixtures were bled into the ASL-5000 to achieve a PETCO2 of 40, 65, and 30 mm Hg. Both PETCO2 and inspired PCO2 were measured at O2 flows of 5, 10, 15, and 20 L/min (adult model) and 2, 4, 6, 8, and 10 L/min (pediatric model).ResultsPETCO2 decreased to varying degrees as O2 flow increased, depending upon the breathing pattern. Although all devices appeared to perform reasonably well under normal and hyperventilation conditions, the clinically expedient method was associated with substantially more CO2 rebreathing. PETCO2 usually deteriorated more under simulated hypoventilation, regardless of the measurement method.ConclusionsBoth of the specially designed O2 capnography masks provided reasonably stable PETCO2 without significant CO2 rebreathing at the commonly used O2 flows. Because of their open design, PETCO2 measured at high O2 flows may produce artificially lower readings that may not reflect arterial CO2 levels compared with lower O2 flows.Copyright © 2017 by Daedalus Enterprises.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.