-
Anesthesia and analgesia · Nov 2017
Observational StudyFeasibility of Automated Propofol Sedation for Transcatheter Aortic Valve Implantation: A Pilot Study.
- Cédrick Zaouter, Thomas M Hemmerling, Stefano Mion, Lionel Leroux, Alain Remy, and Alexandre Ouattara.
- *Centre Hospitalier Universitaire (CHU) de Bordeaux, Service d'Anesthésie-Réanimation II, F-33000 Bordeaux, France; †Department of Anaesthesia, Division of Experimental Surgery, Arnold and Blema Steinberg Simulation Centre, McGill University, Montreal, Canada; ‡CHU de Bordeaux, Service de cardiologie, F-33000 Bordeaux, France; §University Bordeaux, Adaptation cardiovasculaire à l'ischémie, U1034, F-33600 Pessac, France; and ‖INSERM, Adaptation cardiovasculaire à l'ischémie, U1034, F-33600 Pessac, France.
- Anesth. Analg. 2017 Nov 1; 125 (5): 1505-1512.
BackgroundRecently, several trials have shown that closed-loop sedation is feasible. No study has used automated sedation in extremely frail patients, such as those scheduled for transcatheter aortic valve implantation (TAVI). We developed and tested a novel automated sedation system for this kind of population and surgery. The system integrates a decision support system that detects respiratory and hemodynamic events via smart alarms, which provide pertinent/related clinical suggestions and treatment options. The main objective was the feasibility of closed-loop sedation, defined as successful automated sedation without manual override. Secondary qualitative observations were clinical and controller performance.MethodsTwenty patients scheduled for elective TAVI were enrolled. Sedation was administered via a closed-loop delivery system designed for propofol. The clinical performance of sedation was the efficacy to maintain a bispectral index (BIS) of 65. To evaluate the sedation performance, BIS values were stratified into 4 categories: excellent, very good, good, and inadequate sedation control, defined as BIS values within 10%, ranging from 11% to 20%, ranging from 21% to 30%, or >30% from the target value, respectively. The controller performance was calculated using Varvel parameters. Critical respiratory and hemodynamic events were documented. The former was defined as peripheral oxygen saturation <92% and/or respiratory rate <8/min, whereas the latter was considered a mean arterial pressure <60 mm Hg and/or heart rate <40 bpm.ResultsAutomated sedation was successful in 19 patients undergoing TAVI. One patient was excluded from the final analysis because of conversion to general anesthesia. The secondary observations revealed that the clinical performance allowed an excellent to good control during 69% (99% confidence interval, 53%-77%; interquartile range, 59%-79%) of the sedation time. Fifteen patients presented critical respiratory episodes, with a median of 3 events per hour of sedation. Six patients presented critical hemodynamic episodes, with a median of 2 events per hour of procedure.ConclusionsThe automated closed-loop sedation system tested could be used successfully for patients scheduled for a TAVI procedure. The results showed a satisfactory clinical performance of sedation control.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.