• Investigative radiology · May 1982

    Comparative Study

    Pulmonary blood volume: correlation of equilibrium radionuclide and dye-dilution estimates.

    • R Slutsky, C Higgins, V Bhargava, K Gerber, J Tubau, D Costello, and M LeWinter.
    • Invest Radiol. 1982 May 1; 17 (3): 233-40.

    AbstractIn fifteen prospective patients with aortic stenosis undergoing transseptal cardiac catheterization, dye-dilution and count-based estimates of pulmonary blood volume (PBV) were performed. Three radionuclide methods were evaluated. Two were based on electrocardiogram (ECG)-gated imaging of the thorax, where pulmonary counts (PC) were corrected for frame-time, venous radioactivity, and either (1) the number of processed heart beats or (2) the total duration of acquisition. The third method involved ungated frame mode acquisitions, where PC were corrected for the duration of acquisition and the venous activity. PC (per channel element) were derived from manual assignments of the right lung. All methods correlated well with standard dye-dilution techniques (r greater than 0.82), though at greater volumes it was clear that count-based methods underestimated the dye-dilution values. In five acutely instrumented, anesthetized dogs, radionuclide (ungated formula) and dye-dilution estimates of PBV were made during multiple interventions (19 data points). The five control count volumes as well as the 14 separate intervention points correlated well (r greater than 0.89). It is concluded that PC from equilibrium blood pool images reflect PBV and that induced changes in PC can be utilized as a reflection of changes in PBV.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…