Am. J. Respir. Crit. Care Med. · Aug 2017
Bedside Contribution of Electrical Impedance Tomography to Set Positive End-Expiratory Pressure for ECMO-Treated Severe ARDS Patients.
- Guillaume Franchineau, Nicolas Bréchot, Guillaume Lebreton, Guillaume Hekimian, Ania Nieszkowska, Jean-Louis Trouillet, Pascal Leprince, Jean Chastre, Charles-Edouard Luyt, Alain Combes, and Matthieu Schmidt.
- 1 INSERM, UMRS_1166-ICAN, Institute of Cardiometabolism and Nutrition, Université Pierre et Marie Curie Univ Paris 06, Paris, France; and.
- Am. J. Respir. Crit. Care Med. 2017 Aug 15; 196 (4): 447-457.
RationaleOptimal positive end-expiratory pressure (PEEP) is unknown in patients with severe acute respiratory distress syndrome (ARDS) on extracorporeal membrane oxygenation receiving mechanical ventilation with very low tidal volume.ObjectivesTo evaluate the ability of electrical impedance tomography (EIT) to monitor a PEEP trial and to derive from EIT the best compromise PEEP in this setting.MethodsA decremental PEEP trial (20-0 cm H2O) in 5 cm H2O steps was monitored by EIT, with lung images divided into four ventral-to-dorsal horizontal regions of interest. The EIT-based PEEP providing the best compromise between overdistention and collapsed zones was arbitrarily defined as the lowest pressure able to limit EIT-assessed collapse to less than or equal to 15% with the least overdistention. Driving pressure was maintained constant at 14 cm H2O in pressure controlled mode.Measurements And Main ResultsTidal volume, static compliance, tidal impedance variation, end-expiratory lung impedance, and their respective regional distributions were visualized at each PEEP level in 15 patients on extracorporeal membrane oxygenation. Low tidal volume (2.9-4 ml/kg ideal body weight) and poor compliance (12.1-18.7 ml/cm H2O) were noted, with significantly higher tidal volume and compliance at PEEP10 and PEEP5 than PEEP20. EIT-based best compromise PEEPs were 15, 10, and 5 cm H2O for seven, six, and two patients, respectively, whereas PEEP20 and PEEP0 were never selected.ConclusionsThe broad variability in optimal PEEP observed in these patients with severe ARDS under extracorporeal membrane oxygenation reinforces the need for personalized titration of ventilation settings. EIT may be an interesting noninvasive bedside tool to provide real-time monitoring of the PEEP impact in these patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.