• Respiratory care · Apr 2017

    Comparative Study

    Accuracy of Oxygen Consumption and Carbon Dioxide Elimination Measurements in 2 Breath-by-Breath Devices.

    • Craig D Smallwood, John N Kheir, Brian K Walsh, and Nilesh M Mehta.
    • Division of Critical Care Medicine, Department of Anesthesiology, Perioperative and Pain Medicine craig.smallwood@childrens.harvard.edu.
    • Respir Care. 2017 Apr 1; 62 (4): 475-480.

    BackgroundAlthough accurate quantification of oxygen consumption (V̇O2 ) and carbon dioxide elimination (V̇CO2 ) provides important insights into a patient's nutritional and hemodynamic status, few devices exist to accurately measure these parameters in children. Therefore, we assessed the accuracy and agreement of 2 devices currently on the market using a pediatric in vitro model of gas exchange.MethodsWe utilized a Huszczuk simulation model, which simulates oxygen consumption and carbon dioxide production using gas dilution, to examine the accuracy of two FDA-cleared respiratory modules (E-COVX and E-sCAiOVX-00). V̇O2 and V̇CO2 were set at 20, 40, 60, and 100 mL/min, ranges typical for infant and pediatric patients. Bland-Altman analysis was used to calculate the bias and limits of agreement of each device relative to simulated values for V̇O2 and V̇CO2 .ResultsThe E-COVX mean percentage bias (limits of agreement) was -26.3% (-36.1 to -16.6%) and -39.3% (-47.5 to -31.1%) for V̇O2 and V̇CO2 , respectively. The mean bias (limits of agreement) for the E-aCAiOVX-00 was -0.5% (-13.3 to 12.3%) and -6.0% (-13.8 to 1.7%) for V̇O2 and V̇CO2 , respectively.ConclusionsThe E-COVX demonstrated bias and limits of agreement that were not clinically acceptable; therefore, application of this module to pediatric patients would not be recommended. The new module, E-sCAiOVX, demonstrated acceptable bias and limits of agreement for the V̇O2 and V̇CO2 in the range 40-100 mL/min (which corresponds to patients in the range of ∼5-16 kg).Copyright © 2017 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…