Observational Study
Can calculation of energy expenditure based on CO2 measurements replace indirect calorimetry?
- Taku Oshima, Séverine Graf, Claudia-Paula Heidegger, Laurence Genton, Jérôme Pugin, and Claude Pichard.
- Clinical Nutrition, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1211, Geneva 14, Switzerland. Oshima.Taku@hcuge.ch.
- Crit Care. 2017 Jan 21; 21 (1): 13.
BackgroundMethods to calculate energy expenditure (EE) based on CO2 measurements (EEVCO2) have been proposed as a surrogate to indirect calorimetry. This study aimed at evaluating whether EEVCO2 could be considered as an alternative to EE measured by indirect calorimetry.MethodsIndirect calorimetry measurements conducted for clinical purposes on 278 mechanically ventilated ICU patients were retrospectively analyzed. EEVCO2 was calculated by a converted Weir's equation using CO2 consumption (VCO2) measured by indirect calorimetry and assumed respiratory quotients (RQ): 0.85 (EEVCO2_0.85) and food quotient (FQ; EEVCO2_FQ). Mean calculated EEVCO2 and measured EE were compared by paired t test. Accuracy of EEVCO2 was evaluated according to the clinically relevant standard of 5% accuracy rate to the measured EE, and the more general standard of 10% accuracy rate. The effects of the timing of measurement (before or after the 7th ICU day) and energy provision rates (<90 or ≥90% of EE) on 5% accuracy rates were also analyzed (chi-square tests).ResultsMean biases for EEVCO2_0.85 and EEVCO2_FQ were -21 and -48 kcal/d (p = 0.04 and 0.00, respectively), and 10% accuracy rates were 77.7 and 77.3%, respectively. However, 5% accuracy rates were 46.0 and 46.4%, respectively. Accuracy rates were not affected by the timing of the measurement, or the energy provision rates at the time of measurements.ConclusionsCalculated EE based on CO2 measurement was not sufficiently accurate to consider the results as an alternative to measured EE by indirect calorimetry. Therefore, EE measured by indirect calorimetry remains as the gold standard to guide nutrition therapy.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.