• Der Anaesthesist · Mar 2017

    Randomized Controlled Trial

    [Sciatic nerve block "out-of-plane" distal to the bifurcation: effective and safe].

    • T Geiser, J Apel, O Vicent, and J Büttner.
    • Abteilung für Anästhesiologie und Intensivmedizin, Berufsgenossenschaftliche Unfallklinik Murnau, Murnau am Staffelsee, Deutschland. geiser@bgu-murnau.de.
    • Anaesthesist. 2017 Mar 1; 66 (3): 177-185.

    BackgroundUltrasound guided distal sciatic nerve block (DSB) at bifurcation level shows fast onset and provides excellent success rates. However, its safe performance might be difficult for the unexperienced physician. Just slightly distal to the bifurcation, the tibial nerve (TN) and common fibular nerve (CFN) can be shown clearly separated from each other. Therefore, we investigated if a block done here would provide similar quality results compared to the DSB proximally to the division, with a potentially lower risk of nerve damage.MethodsIn this randomized, prospective trial, 56 patients per group received either a DSB distal to the bifurcation "out-of-plane" (dist.) or proximally "in-plane" (prox.) with 30 ml of Mepivacaine 1% each. Success was tested by a blinded examiner after 15 and 30 min respectively (sensory and motor block of TN and CFN: 0 = none, 2 = complete, change of skin temperature). Videos of the blocks were inspected by an independent expert retrospectively with regard to the spread of the local anesthetic (LA) and accidental intraneural injection.ResultsCumulative single nerve measurements and temperature changes revealed significant shorter onset and better efficacy (dist/prox: 15 min: 3.13 ± 1.86/1.82 ± 1.62; 30 min: 5.73 ± 1.92/3.21 ± 1.88; T15 min: 30.3 ± 3.48/28.0 ± 3.67, T30 min. 33.0 ± 2.46/30.6 ± 3.86; MV/SD; ANOVA; p < 0.01) combined with a higher rate of subparaneural spread in the dist. group (41/51 vs.12/53; χ2; p < 0,01). Procedure times were similar. There were no complications in either group.DiscussionThe subparaneural spread of the LA turned out to be crucial for better results in the distal group. The steep angle using the out-of-plane approach favors needle penetration through the paraneural sheath. The distance between the branches allows the safe application of the LA, so an effective block can be done with just one injection.ConclusionDSB slightly distal to the bifurcation, in an out-of-plane technique between the TN and CFN, can be done fast, effectively and safe.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.