Paediatric anaesthesia · Mar 2017
Observational StudyElectroencephalographic discontinuity during sevoflurane anesthesia in infants and children.
- Laura Cornelissen, Ann M Bergin, Kimberly Lobo, Carolina Donado, Janet S Soul, and Charles B Berde.
- Department of Anesthesiology, Perioperative & Pain Medicine, Boston Children's Hospital, Boston, MA, USA.
- Paediatr Anaesth. 2017 Mar 1; 27 (3): 251-262.
BackgroundDeep anesthesia in adults may be associated with electroencephalographic (EEG) suppression and higher rates of postoperative complications. Little is known about the impact of anesthetic depth on short- or long-term outcomes in pediatrics. Brain activity monitoring may complement clinical signs of anesthetic depth. This prospective observational study aimed to assess the frequency and degree of profound EEG suppression using multichannel EEG in children during sevoflurane general anesthesia.MethodsChildren aged 0-40 months who required general anesthesia for elective surgery were included. Continuous EEG recordings were performed starting from when anesthesia began and until recovery. Discontinuity was defined as EEG amplitude <25 uV, lasting ≥2 s, and observed in all electrodes across the scalp. Frequency, duration, and inter-event interval of discontinuity events were measured. Relationships between discontinuity events and postnatal age, endtidal sevoflurane concentration (etSEVO), and multiple clinical parameters were analyzed.ResultsDiscontinuity events were observed in 35/68 children, with a median duration of 10 s (95%CI: 8-12) and a median of 4 events per patient (95%CI: 2-7). Children who had discontinuity events were younger (5.5 months, 95%CI: 3.6-6.5) compared to children who did not have discontinuity events (10.2 months, 95%CI: 6.1-14); (difference between medians, 4.7 months, 95%CI: 2.3-8, P = 0.0002). Younger infants exhibited a higher number of discontinuity events, and the incidence decreased with postnatal age (r68 = -0.53, P < 0.0001). The majority of discontinuity events were observed during the first 30 min of anesthesia (66.4% total events), where etSEVO was >3%. Few discontinuity events were observed during maintenance and none during emergence. Blood pressure, heart rate, tissue oxygen saturation, and endtidal CO2 partial pressure did not change during these events.ConclusionsElectroencephalographic monitoring may complement clinical signs in providing information about brain homeostasis during general anesthesia. The impact of discontinuity events on immediate and long-term outcomes merits further study.© 2017 John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.