    Volume and Pressure Delivery During Pediatric High-Frequency Oscillatory Ventilation.

    • Ronald Wong, Timothy Deakers, Justin Hotz, Robinder G Khemani, Patrick A Ross, and Christopher J Newth.
    • 1Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, Los Angeles, CA. 2Department of Pediatrics, Keck School of Medicine, University of Southern California, Los Angeles, CA. 3Department of Pediatric Critical Care, Geisinger Medical Center, Janet Weis Children's Hospital, Danville, PA.
    • Pediatr Crit Care Me. 2017 Apr 1; 18 (4): e189-e194.

    ObjectiveIdentify variables independently associated with delivered tidal volume (VT) and measured mean airway pressure during high-frequency oscillatory ventilation across the range of pediatric endotracheal tube sizes.DesignIn vitro study.SettingResearch laboratory.InterventionsAn in vitro bench model of the intubated pediatric respiratory system during high-frequency oscillatory ventilation was used to obtain delivered VT and mean airway pressure (in the distal lung) for various endotracheal tube sizes. Measurements were taken at different combinations of ventilator set mean airway pressure (Paw), amplitude (ΔP), frequency, and test lung compliance. Multiple regression analysis was used to construct multivariable models predicting delivered VT and mean airway pressure.Measurements And Main ResultsVariables independently associated with higher delivered VT for all endotracheal tube sizes include higher ΔP (p < 0.001), lower frequency (p < 0.001), and higher test lung compliance (p < 0.001). A multiplicative interaction between frequency and ΔP magnifies the delivered VT when ΔP is high and frequency is low (p < 0.001). Delivered mean airway pressure becomes lower than set Paw as ΔP increases (p < 0.001) and frequency increases (p < 0.05). Ventilator set Paw is the largest determinant of delivered mean airway pressure; however, increasing ΔP resulted in a lower delivered mean airway pressure. For example, in a 4.0 mm ID endotracheal tube, increasing ΔP by 10 cm H2O resulted in an average decrease of delivered mean airway pressure by 4.5%.ConclusionsThis is the first study to quantify the interaction between ΔP and frequency in delivered VT and the effect of ΔP and frequency on delivered mean airway pressure. These results demonstrate the need to measure or estimate VT and delivered pressures during high-frequency oscillatory ventilation and may be useful in determining optimal strategies for lung protective ventilation during high-frequency oscillatory ventilation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…