- Takayuki Ogura, Alan Kawarai Lefor, Mitsunobu Nakamura, Kenji Fujizuka, Kousuke Shiroto, and Minoru Nakano.
- Advanced Medical Emergency Department and Critical Care Center, Japan Red Cross Maebashi Hospital, Maebashi, Japan; Department of Emergency Medicine, Jichi Medical University, Tochigi, Japan.
- J Emerg Med. 2017 May 1; 52 (5): 715-722.
BackgroundIn trauma resuscitation with resuscitative endovascular balloon occlusion of the aorta (REBOA), urgent and accurate placement of the catheter in the resuscitation area without fluoroscopy can shorten the time from admission to REBOA, allowing rapid, temporary control of bleeding.DiscussionThe experience-based protocol in our center for ultrasound-guided REBOA in the resuscitation area without fluoroscopy is as follows: the femoral artery is punctured and a guidewire inserted; sonography is used to verify that the guidewire is in the abdominal aorta; the position of the balloon is confirmed with ultrasound after estimating the distance to the clavicle, and the pressure in the radial artery and sheath is used to monitor correct positioning; connect the pressure transducer to the catheter sheath for continuous monitoring of the blood pressure in the sheath, and inflate the balloon until the blood pressure tracing at the sheath has disappeared; check the pulse in the left radial artery, and withdraw the catheter slightly if the pulse in the radial artery is not palpable or is decreased (if this pulse is not palpable or decreased, the balloon is in the aortic arch). In this retrospective review of our REBOA protocol, between April 2012 and March 2016, 34 patients were enrolled. Two patients had complications, including dissection of the femoral artery in one and difficult percutaneous vascular access in another. Median time needed to complete the procedure was 8 min. Overall, 24 of 34 patients survived more than 24 h (72%), and overall mortality was 47%. Patients who lived more than 24 h, and then died had severe traumatic brain injury or septic shock.ConclusionsUltrasound-guided REBOA is presented. Monitoring the blood pressure in the left radial artery allows us to determine adequate positioning of the balloon, and the blood pressure in the catheter sheath located in the femoral artery should also be monitored to prevent aortic injuries caused by the overinflation of the balloon.Copyright © 2017 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.