• Anesthesia and analgesia · Jun 2017

    Comparative Study Clinical Trial

    Influence of Fraction of Inspired Oxygen on Noninvasive Hemoglobin Measurement: Parallel Assessment of 2 Monitors.

    • Etienne Gayat, Nicolas Imbert, Ariane Roujansky, Léa Lemasle, and Marc Fischler.
    • From the *Department of Anesthesiology and Critical Care Medicine, Saint Louis - Lariboisière-Fernand Widal University Hospital; †Medical School, Paris Diderot University, Paris, France; ‡UMR-S942, INSERM, Paris, France; and §Department of Anaesthesia, Hôpital Foch, Suresnes, France, and Université Versailles Saint-Quentin en Yvelines, France.
    • Anesth. Analg. 2017 Jun 1; 124 (6): 1820-1823.

    BackgroundPrevious reports have brought specific attention to the relationship between oxygenation of the patient and the accuracy of noninvasive measurement of hemoglobin (Hb) using an optical sensor. This study aimed to assess prospectively the relationship between fraction of inspired oxygen (FIO2) and the bias of the measurement of Hb by the use of 2 different noninvasive monitors compared with the classic invasive technique.MethodsForty-four patients were included prospectively. In each individual, Hb level was determined noninvasively by monitor Pronto-7™ (Masimo Corporation, Irvine, CA) and by monitor NBM-200MP™ (OrSense Ltd, Petah-Tikva, Israel), with the probe placed on 2 fingers on the same hand of the patient. Three measures were performed, first under breathing air and 2 others when fraction of expired oxygen rose to 50% ± 5% and to 90 ± 5%. Simultaneously, a nurse collected a venous blood sample, which was sent immediately to the hematology laboratory for Hb measurement. The main outcome measurement was the mean bias between noninvasive and invasive measurements.ResultsResults show no change in median bias [interquartile range] with FIO2 for Pronto-7 (from 1.1 g/dL [0.0-2.0] in FIO2 21% to 1.0 g/dL [0.2-1.5] in FIO2 100%), but increasingly negative median bias with increasing FIO2 for NBM-200MP (from -0.3 g/dL [-1.3 to 0.3] in FIO2 21% to -0.8 g/dL [-1.5 to -0.1] in FIO2 100%, P = .04).DiscussionThis study showed that noninvasive measurement of Hb could be influenced by inspired fraction of oxygen when the monitor NBM-200MP is used.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.