• Reg Anesth Pain Med · Jul 2017

    Use of 3-Dimensional Printing to Create Patient-Specific Thoracic Spine Models as Task Trainers.

    • Jelliffe Jeganathan, Yanick Baribeau, Jeffrey Bortman, Feroze Mahmood, Marc Shnider, Muneeb Ahmed, Azad Mashari, Rabia Amir, Yannis Amador, and Robina Matyal.
    • From the *Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA; †Department of Radiology, Division of Vascular & Interventional Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA; and ‡Department of Anesthesia and Pain Management, Toronto General Hospital, University Health Network, University of Toronto, Toronto, Canada.
    • Reg Anesth Pain Med. 2017 Jul 1; 42 (4): 469-474.

    Background And ObjectivesThoracic epidural anesthesia is a technically challenging procedure with a high failure rate of 24% to 32% nationwide. Residents in anesthesiology have limited opportunities to practice this technique adequately, and there are no training tools available for this purpose. Our objective was to build a low-cost patient-specific thoracic epidural training model.MethodsWe obtained thoracic computed tomography scan data from patients with normal and kyphotic spine. The thoracic spine was segmented from the scan, and a 3-dimensional model of the spine was generated and printed. It was then placed in a customized wooden box and filled with different types of silicone to mimic human tissues. Attending physicians in our institution then tested the final model. They were asked to fill out a brief questionnaire after the identification of the landmarks and epidural space using ultrasound and real-time performance for a thoracic epidural on the model (Supplemental Digital Content 1, http://links.lww.com/AAP/A197). Likert scoring system was used for scoring.ResultsThe time to develop this simulator model took less than 4 days, and the materials cost approximately $400. Fourteen physicians tested the model for determining the realistic sensation while palpating the spinous process, needle entry through the silicone, the "pop" sensation and ultrasound fidelity of the model. Whereas the tactile fidelity scores were "neutral" (3.08, 3.06, and 3.0, respectively), the ultrasound guidance and overall suitability for residents were highly rated as being the most realistic (4.85 and 4.0, respectively).ConclusionsIt is possible to develop homemade, low-cost, patient-specific, and high-fidelity ultrasound guidance simulators for resident training in thoracic epidurals using 3-dimensional printing technology.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…